MAX4773EUT-T Maxim Integrated, MAX4773EUT-T Datasheet - Page 6

no-image

MAX4773EUT-T

Manufacturer Part Number
MAX4773EUT-T
Description
Power Switch ICs - Power Distribution
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX4773EUT-T

Number Of Outputs
1
Operating Supply Voltage
2 V to 4.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOT-23-6
Minimum Operating Temperature
- 40 C
The MAX4772/MAX4773 are forward/reverse current-
limited switches that operate from a 2.0V to 4.5V input
voltage range and guarantee a 200mA or 500mA mini-
mum current-limit threshold when driving SEL low or
high, respectively. The voltage drop across an internal
sense resistor is compared to two reference voltages to
indicate a forward or reverse current-limit fault. When
the load current exceeds the preset current limit for
greater than the fault-blanking time, the switch opens.
The MAX4773 has an autoretry function that turns on
the switch again after an internal retry time expires. If
the faulty load condition is still present after the blank-
ing time, the switch turns off again and the cycle is
repeated. If the faulty load condition is not present, the
switch remains on.
The MAX4772 does not have the autoretry option and
the switch remains in latch-off mode until the ON pin or
the input power is cycled from high to low and then
high again.
200mA/500mA Selectable
Current-Limit Switches
Figure 1. Functional Diagram
6
_______________________________________________________________________________________
Detailed Description
ON
IN
LOGIC
SEL
REVERSE-CURRENT DETECTOR
FORWARD-CURRENT
DETECTOR
The MAX4772/MAX4773 SEL logic input sets the
desired minimum current-limit threshold to 200mA or
500mA. Connect SEL low or leave floating for 200mA
current limit and high for the 500mA current limit.
During power-up, if SEL is low or floating, the current limit
is set to 200mA. The MAX4772/MAX4773 uses an internal
pulldown resistor (100µA, max) to set the default current
limit to 200mA when SEL is floating. After the first low-to-
high transition, the pulldown resistor is internally discon-
nected and the level on SEL determines the current limit
(SEL = low, 200mA and SEL = high, 500mA).
During power-up, if SEL and V
rent limit is immediately set to 500mA.
Figures 2 and 3 illustrate the two different modes of
power-up sequence for the MAX4772/MAX4773. In
Figure 2, the switch powers up, V
transition on SEL changes the current limit from 200mA to
500mA. In Figure 3, the switch powers up in the 500mA
current-limit mode with SEL and IN rising simultaneously.
The microprocessor’s GPIO must be able to source the
100µA drive current for the MAX4772/MAX4773 500mA
current-limit operation. After the current limit has been set
to 500mA, the 100µA driving current is no longer needed.
MAX4772/MAX4773
BLANKING TIME
CIRCUITRY
Current-Limit Threshold Selection
GND
N
FLAG
OUT
IN
rise together, the cur-
IN
≥ 2V, a low-to-high

Related parts for MAX4773EUT-T