M24C32-RDW6TP STMicroelectronics, M24C32-RDW6TP Datasheet - Page 22

IC EEPROM 32KBIT 400KHZ 8TSSOP

M24C32-RDW6TP

Manufacturer Part Number
M24C32-RDW6TP
Description
IC EEPROM 32KBIT 400KHZ 8TSSOP
Manufacturer
STMicroelectronics
Datasheets

Specifications of M24C32-RDW6TP

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
32K (4K x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-TSSOP
Organization
4 K x 8
Interface Type
2-Wire
Maximum Clock Frequency
0.4 MHz
Access Time
900 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.8 V
Maximum Operating Current
0.8 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.8 V, 5.5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8643-2
M24C32-RDW6TP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24C32-RDW6TP
Manufacturer:
ST
Quantity:
5 647
Part Number:
M24C32-RDW6TP
0
Part Number:
M24C32-RDW6TP(PBFREE)
Manufacturer:
ST
0
Part Number:
M24C32-RDW6TP/K
Manufacturer:
ST
0
Part Number:
M24C32-RDW6TP/P
Manufacturer:
ST
0
Part Number:
M24C32-RDW6TPCBA
Manufacturer:
ST
0
Part Number:
M24C32-RDW6TPCTA
Manufacturer:
ST
0
Device operation
4.18
4.19
22/42
Read the lock status (M24C32-D)
The locked/unlocked status of the Identification page can be checked by issuing a specific
truncated command [Identification Page Write instruction + one data byte]: this data byte will
be acknowledged if the Identification page is unlocked, while it will not be acknowledged if
the Identification page is locked.
Once the acknowledge bit of this data byte is read, it is recommended to generate a Start
condition followed by a Stop condition, so that:
Acknowledge in Read mode
For all Read commands, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
Start: the truncated command is not executed because the Start condition resets the
device internal logic,
Stop: the device is then set back into Standby mode by the Stop condition.
th
bit time. If the bus master does not drive Serial Data (SDA) low during this
Doc ID 4578 Rev 18
M24C32-DF, M24C32-W, M24C32-R, M24C32-F

Related parts for M24C32-RDW6TP