T6818-TUQY Atmel, T6818-TUQY Datasheet - Page 6

no-image

T6818-TUQY

Manufacturer Part Number
T6818-TUQY
Description
IC DRIVER TRPL HALFBRIDGE 14SOIC
Manufacturer
Atmel
Type
Half Bridger
Datasheet

Specifications of T6818-TUQY

Input Type
Serial
Number Of Outputs
3
On-state Resistance
500 mOhm
Current - Output / Channel
1.5A
Current - Peak Output
2A
Voltage - Supply
7 V ~ 40 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
14-SOIC (3.9mm Width), 14-SOL
For Use With
ATAB6818 - BOARD EVAL FOR T6818/ATA6828
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T6818-TUQY
Manufacturer:
ST
0
3.2
3.3
3.4
3.5
3.6
6
Power-supply Fail
Open-load Detection
Overtemperature Protection
Short-circuit Protection
Inhibit
T6818
In case of undervoltage at pin VS, the Power-Supply Fail bit (PSF) in the output register is set
and all outputs are disabled. To detect an undervoltage, its duration has to last longer than the
undervoltage detection delay time t
age recovers normal operation value. The PSF bit stays high until it is reset by the SRR bit in the
input register.
If the current through a high-side or low-side switch in ON-state stays below the open-load
detection threshold, the open-load detection bit (OPL) in the output register is set.
The OPL bit stays high until it is reset by the SRR bit in the input register. To detect an open
load, its duration has to last longer than the open-load detection delay time t
If the junction temperature of one or more output stages exceeds the thermal prewarning thresh-
old, T
temperature falls below the thermal prewarning threshold, T
bit can be read without transferring a complete 16-bit data word. The status of TP is available at
pin DO with the falling edge of CS. After the microcontroller has read this information, CS is set
high and the data transfer is interrupted without affecting the status of input and output registers.
If the junction temperature of one or more output stages exceeds the thermal shutdown thresh-
old, T
low. The outputs can be enabled again when the temperature falls below the thermal shutdown
threshold, T
warning and shutdown threshold avoids oscillations.
The output currents are limited by a current regulator. Overcurrent detection is activated by writ-
ing a high to the OCS bit in the input register. When the current in an output stage exceeds the
overcurrent limitation and shutdown threshold, it is switched off after a delay time (t
short-circuit detection bit (SCD) is set and the corresponding status bit in the output register is
set to low. For OCS = low the overcurrent shutdown is inactive. The SCD bit is also set if the cur-
rent exceeds the overcurrent limitation and shutdown threshold, but the outputs are not affected.
By writing a high to the SRR bit in the input register the SCD bit is reset and the disabled outputs
are enabled.
0 V applied to pin 10 (INH) inhibits the T6818.
All output switches are then turned off and switched to tri-state. The data in the output register
are deleted. The current consumption is reduced to less than 5 µA at pin VS and less than 25 µA
at pin VCC. The output switches can be activated again by switching pin 10 (INH) to 5 V which
initiates an internal power-on reset.
j switch off
jPW set
jswitch on
, the temperature prewarning bit (TP) in the output register is set. When the
, all outputs are disabled and the corresponding bits in the output register are set to
and the SRR bit in the input register is set to high. Hysteresis of thermal pre-
dUV
. The outputs are enabled immediately when supply volt-
jPW reset
, the bit TP is reset. The TP
dSd
.
4530H–BCD–09/09
dSd
). The

Related parts for T6818-TUQY