MAX1619MEE Maxim Integrated Products, MAX1619MEE Datasheet - Page 10

IC TEMP SENSOR W/ALARM 16-QSOP

MAX1619MEE

Manufacturer Part Number
MAX1619MEE
Description
IC TEMP SENSOR W/ALARM 16-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1619MEE

Function
Thermometer, Thermostat
Topology
ADC, Comparator, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-55°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAX1619MEE
Manufacturer:
MAXIM
Quantity:
10
Part Number:
MAX1619MEE
Manufacturer:
MAXIM
Quantity:
14
Part Number:
MAX1619MEE
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1619MEE+
Manufacturer:
Maxim
Quantity:
371
Part Number:
MAX1619MEE+
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAX1619MEE+T
Manufacturer:
MAXIM
Quantity:
1 403
the MAX1619 can be forced to perform A/D conversions
via the one-shot command, despite the RUN/STOP bit
being high.
Activate hardware standby mode by forcing the STBY
pin low. In a notebook computer, this line may be con-
nected to the system SUSTAT# suspend-state signal.
The STBY pin low state overrides any software conversion
command. If a hardware or software standby command
is received while a conversion is in progress, the conver-
sion cycle is truncated, and the data from that conversion
is not latched into either temperature reading register.
The previous data is not changed and remains available.
The OVERT output continues to function in both hard-
ware and software standby modes. If the overtemp lim-
its are adjusted while in standby mode, the digital
comparator checks the new values and puts the OVERT
pin in the correct state based on the last valid ADC con-
version. The last valid ADC conversion may include a
conversion performed using the one-shot command.
Supply-current drain during the 125ms conversion peri-
od is always about 450µA. Slowing down the conversion
rate reduces the average supply current (see Typical
Remote/Local Temperature Sensor with Dual-
Alarm Outputs and SMBus Serial Interface
Write Byte Format
Read Byte Format
Send Byte Format
S = Start condition
P = Stop condition
Figure 3. SMBus Protocols
10
S
S
S
______________________________________________________________________________________
ADDRESS
Slave Address:
equivalent to
chip-select line
ADDRESS
7 bits
7 bits
Slave Address:
equivalent to chip-select
line of a 3-wire interface
ADDRESS
7 bits
WR
Shaded = Slave transmission
/// = Not acknowledged
WR
ACK
ACK
WR
Command Byte: sends com-
mand with no data; usually
used for one-shot command
COMMAND
8 bits
Command Byte: selects
which register you are
reading from
COMMAND
8 bits
ACK
ACK
Command Byte: selects
which register you are
writing to
ACK
COMMAND
P
8 bits
S
Operating Characteristics ). Between conversions, the
instantaneous supply current is about 25µA due to the
current consumed by the conversion rate timer. In
standby mode, supply current drops to about 3µA. At
very low supply voltages (under the power-on-reset
threshold), the supply current is higher due to the
address pin bias currents. It can be as high as 100µA,
depending on ADD0 and ADD1 settings.
From a software perspective, the MAX1619 appears as a
set of byte-wide registers that contain temperature data,
alarm threshold values, or control bits. A standard
SMBus 2-wire serial interface is used to read tempera-
ture data and write control bits and alarm threshold data.
Each A/D channel within the device responds to the
same SMBus slave address for normal reads and writes.
The MAX1619 employs four standard SMBus protocols:
Write Byte, Read Byte, Send Byte, and Receive Byte
(Figure 3). The shorter Receive Byte protocol allows
quicker transfers, provided that the correct data register
was previously selected by a Read Byte instruction. Use
caution with the shorter protocols in multi-master sys-
Receive Byte Format
S
Slave Address: repeated
due to change in data-
flow direction
ADDRESS
7 bits
ADDRESS
ACK
7 bits
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
RD
DATA
8 bits
RD
ACK
SMBus Digital Interface
ACK
Data Byte: reads from
the register set by the
command byte
Data Byte: reads data from
the register commanded
by the last Read Byte or
Write Byte transmission;
also used for SMBus Alert
Response return address
DATA
8 bits
DATA
8 bits
ACK
///
///
P
1
P
P

Related parts for MAX1619MEE