ADUM3300CRWZ Analog Devices Inc, ADUM3300CRWZ Datasheet - Page 10

no-image

ADUM3300CRWZ

Manufacturer Part Number
ADUM3300CRWZ
Description
IC DIGITAL ISOLATOR 3CH 16-SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM3300CRWZ

Propagation Delay
27ns
Inputs - Side 1/side 2
3/0
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
120Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
3
Supply Current
54mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3300CRWZ
Manufacturer:
AD
Quantity:
6 847
ADuM3300/ADuM3301
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input to Output)
Capacitance (Input to Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
2
REGULATORY INFORMATION
The ADuM330x is approved by the organizations listed in Table 5. See Table 10 and the Insulation Lifetime section for details regarding
recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
Recognized under UL 1577
Component Recognition
Program
Double/reinforced insulation,
2500 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
The device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL1577, each ADuM330x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 second (current leakage detection limit = 5 μA).
In accordance with DIN V VDE V 0884-10, each ADuM330x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). An asterisk (*) marking branded on the component designates DIN V VDE V 0884-10 approval.
1
2
1
1
CSA
Approved under CSA Component Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
800 V rms (1131 V peak) maximum working voltage
Reinforced insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (566 V peak) maximum working voltage
File 205078
Symbol Value
L(I01)
L(I02)
CTI
Symbol
R
C
C
θ
θ
I-O
I-O
I
JCI
JCO
Rev. A | Page 10 of 20
2500
7.7 min
8.1 min
0.017 min mm
>175
IIIa
Min
Unit
V rms 1-minute duration
mm
mm
V
Typ
10
2.2
4.0
33
28
12
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Max
Unit
Ω
pF
pF
°C/W
°C/W
VDE
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10): 2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
2

Related parts for ADUM3300CRWZ