SU3000RMNAFTA Tripp Lite, SU3000RMNAFTA Datasheet - Page 2

no-image

SU3000RMNAFTA

Manufacturer Part Number
SU3000RMNAFTA
Description
UPS TRUEONLINE 3.0KVA 2400W 9OUT
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
Power Supply Regulatorr
Datasheet

Specifications of SU3000RMNAFTA

Power - Rated
3kVA / 2400W
Ac Outlets
9 (UPS)
Features
DB9 and USB Communications, Rack Mount
Backup Time - Max Load
6 minutes
Voltage - Output Per Connector
120V (4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R)
Voltage - Input
208V / 30A
Cord Length
10' (3.05m)
Ac Input Connector
NEMA L5-30P
Connector - Ac Output
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Size
26.00" L x 17.75" W x 5.25" H (660.4mm x 450.9mm x 133.4mm)
Weight
74 lbs (33.6kg)
Ac Output Connector
4 NEMA 5-15R, 4 NEMA 5-15/20R and 1 NEMA L5-30R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Media Lines Protected
-
Specifications
OUTPUT
Frequency
compatibility
Output VA
Output watts
Output nominal
voltage
Output voltage
regulation
Output frequency
regulation
Overload
protection
Outlet quantity /
type
Customized load
management
receptacles
INPUT
UPS Input cord
length (ft.)
conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 110/120V (+/-2%) values
Standard internal battery set offers 17 minutes runtime at half load (1200W) and 6 minutes at full load (2400W)
Optional BP72V28-3UNAFTA external battery pack increases runtime to 78 minutes at half load (1200W) and 34 minutes at full load
(2400W/multi-pack compatible)
Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure
and requires maintenance
Network interfaces support simultaneous communications via built-in USB, DB9 serial/contact-closure and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current,
battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS
nominal voltage adjustment and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA L5-30P input plug/NEMA 5-15/20R, L5-20R & L5-30R output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each
bank has four outlets)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations; no time consuming connection of internal batteries by user required
Single line TEL/DSL or network ethernet line surge suppression
2 year manufacturer's product warranty; $250,000
50/60 Hz (auto-selectable)
3000
2400
120V AC (100/110/120V)
Maintains full-time sine wave output within 2% of selected nominal, less than 3% total harmonic distortion (linear load) /
5% total harmonic distortion (computer load) (Less than 5% THD on-line and on-battery)
Regulates line frequency to 50/60Hz +/- 0.05Hz
Via 40A input breaker
4 NEMA 5-15R, 4 NEMA 5-15/20R, 1 NEMA L5-30R
2 controllable load banks support load shedding and remote reboot on demand of locked network devices (each bank
has 4 outlets)
10ft / 3m
Ultimate Lifetime Insurance