SU7500RT3U Tripp Lite, SU7500RT3U Datasheet - Page 3

no-image

SU7500RT3U

Manufacturer Part Number
SU7500RT3U
Description
UPS 7.5KVA 6000W 6OUT RACK MOUNT
Manufacturer
Tripp Lite
Series
Smart Online™r
Type
Power Supply Regulatorr
Datasheet

Specifications of SU7500RT3U

Power - Rated
7.5kVA / 6000W
Ac Outlets
6 (UPS)
Features
Rack Mount
Backup Time - Max Load
8 minutes
Voltage - Output Per Connector
208V (200, 208, 230, 220, 240V)
Voltage - Input
208V / 33.7A
Ac Input Connector
Hardwire
Connector - Ac Output
4 NEMA L6-20R and 2 NEMA L6-30R
Size
25.00" L x 17.50" W x 5.14" H (635.0mm x 444.5mm x 130.6mm)
Weight
220 lbs (99.8kg)
Ac Output Connector
4 NEMA L6-20R and 2 NEMA L6-30R
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Cord Length
-
Media Lines Protected
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
DC system voltage
(VDC)
Battery Access
Full load runtime
Half load runtime
Battery Pack
Accessory (optional)
Connects to UPS via
Typical battery
lifespan
Battery recharge rate
VOLTAGE REGULATION
Voltage regulation
description
Overvoltage
correction
Brownout correction
LEDS ALARMS & SWITCHES
Alarms
Switches
Front panel LEDs
SURGE / NOISE SUPPRESSION
EMI / RFI AC noise
suppression
AC suppression
response time
PHYSICAL
Shipping weight
(lbs)
Shipping weight (kg)
Cooling method
Unit Dimensions
(HWD/in)
Unit Dimensions
(HWD/cm)
Shipping
Dimensions
(HWD/in)
Shipping
Dimensions
(HWD/cm)
Unit weight (lbs)
240
User replaceable, hot swappable external battery pack
9 min. (7500VA/6000W)
20 min. (3750VA/3000W)
BP240V10RT3U,
Included 3-wire DC cable
4-6 years
Less than 8 hours to 90% (included battery set only)
On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected
nominal voltage at all times
Maintains continuous operation without using battery power during overvoltages to 276V AC, regulating output within
2% of selected nominal
Maintains continuous operation without using battery power during brownout / undervoltage conditions to 156V AC,
regulating output within 2% of selected nominal
Multi-function audible alarm offers notification of UPS start, backup operation, low battery, overload, UPS fault,
inverter fault, DC bus fault, overtemperature, remote shutdown, shutdown imminent and shutdown complete
Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions
6 LED DISPLAY: line power, bypass, inverter, charger, output AC and battery operation. LED/LCD display panel
easily rotates for viewing in rackmount or tower configurations.
Yes
Instantaneous
331
150.3
Fan
Power Module 5.14 x 17.5 x 25, Battery Pack 5.16 x 17.5 x 25 (Installed depth of power module extends to 32.5
inches once detachable PDU backplate is installed)
Power Module 13.3 x 44.4 x 63.5, Battery Pack 13.4 x 40.6 x 63.5 (Installed depth of power module extends to 82.6
cm once detachable PDU backplate is installed)
39.75 x 31.5 x 23
101 x 80 x 58.4
Power Module 55 lbs., Battery Pack: 136.5 lbs.
BP240V32