NHD-0108HZ-FSW-GBW Newhaven Display, NHD-0108HZ-FSW-GBW Datasheet - Page 8
NHD-0108HZ-FSW-GBW
Manufacturer Part Number
NHD-0108HZ-FSW-GBW
Description
LCD MOD CHAR 1X8 WHITE TRANSFL
Manufacturer
Newhaven Display
Series
NHD-0108HZ-Fr
Datasheet
1.NHD-0108HZ-FSW-GBW.pdf
(8 pages)
Specifications of NHD-0108HZ-FSW-GBW
Display Type
STN - Super-Twisted Nematic
Display Mode
Transflective
Number Of Digits/alpha
8
Outline L X W X H
60.70mm x 33.85mm x 6.25mm
Viewing Area
51.20mm L x 10.16mm W
Backlight
LED - White
Display Format
8 x 1
Character Size
5.02mm H x 7.28mm W
Character Format
5 x 8 Dots
Voltage - Supply
3V
Operating Temperature
-20°C ~ 70°C
Character Count X Line
8 x 1
Module Size (w X H X T)
60.7 mm x 33.85 mm x 10.5 mm
Fluid Type
STN
Background Color
Gray
Voltage Rating
3.3 V
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
LED White
Interface
Parallel
For Use With
NHDEV - BOARD DEV LCD COG TFT 100X95MM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Dot Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
NHD-0108HZ-FSW-GBW
Manufacturer:
Newhaven Display
Quantity:
135
Quality Information
High Temperature storage
Low Temperature storage
High Temperature
Operation
Low Temperature
Operation
High Temperature /
Humidity Operation
Thermal Shock resistance
Vibration test
Static electricity test
Note 1: No condensation to be observed.
Note 2: Conducted after 4 hours of storage at 25
Note 3:
Precautions for using LCDs/LCMs
See Precautions at www.newhavendisplay.com/specs/precautions.pdf
Warranty Information and Terms & Conditions
http://www.newhavendisplay.com/index.php?main_page=terms
Test Item
Test performed on product itself, not inside a container.
storage temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the low thermal
stress for a long time.
Endurance test applying the electric stress
(voltage & current) and the high thermal
with high humidity stress for a long time.
Endurance test applying the electric stress
(voltage & current) during a cycle of low
and high thermal stress.
Endurance test applying vibration to
simulate transportation and use.
Endurance test applying electric static
discharge.
Endurance test applying the high
Content of Test
⁰C, 0%RH.
[8]
+80⁰C , 48hrs
‐30⁰C , 48hrs
+70⁰C 48hrs
‐20⁰C , 48hrs
+40⁰C , 90% RH , 48hrs
0⁰C,30min ‐> 25⁰C,5min ‐>
50⁰C,30min = 1 cycle
10 cycles
10‐55Hz , 15mm amplitude.
60 sec in each of 3 directions
X,Y,Z
For 15 minutes
VS=800V, RS=1.5kΩ, CS=100pF
One time
Test Condition
Note
2
1,2
2
1,2
1,2
3