SFH 482 M E7800 OSRAM Opto Semiconductors Inc, SFH 482 M E7800 Datasheet - Page 2

no-image

SFH 482 M E7800

Manufacturer Part Number
SFH 482 M E7800
Description
EMITTER IR 880NM TO-18
Manufacturer
OSRAM Opto Semiconductors Inc
Datasheet

Specifications of SFH 482 M E7800

Wavelength
880nm
Viewing Angle
60°
Package / Case
TO-18
Current - Dc Forward (if)
200mA
Radiant Intensity (ie) Min @ If
1.6mW/sr @100mA
Voltage - Forward (vf) Typ
1.5V
Orientation
Top View
Mounting Type
Through Hole
Lens Dimensions
4.8 mm x 4.8 mm x 0.2 mm
Lens Shape
Dome
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q62703Q2186
Typ
Type
SFH 480
SFH 480-2/3
SFH 481
SFH 481-1/2
SFH 481-2/3
SFH 482
SFH 482-1/2
SFH 482-2/3
SFH 482-M E7800
1)
2)
3)
3)
2008-11-25
Nicht für Neuentwicklungen / Not for new designs
Die Messung der Strahlstärke und des Halbwinkels erfolgt mit einer Lochblende vor dem Bauteil (Durchmesser der
Lochblende: 2.0 mm; Abstand Lochblende zu Gehäuserückseite: 5.4 mm). Dadurch wird sichergestellt, daβ bei der
Strahlstärkemessung nur diejenige Strahlung in Achsrichtung bewertet wird, die direkt von der Chipoberfläche
austritt. Von der Bodenplatte reflektierte Strahlung (vagabundierende Strahlung) wird dagegen nicht bewertet. Diese
Reflexionen sind besonders bei Abbildungen der Chipoberfläche über Zusatzoptiken störend (z.B. Lichtschranken
groβer Reichweite). In der Anwendung werden im allgemeinen diese Reflexionen ebenfalls durch Blenden
unterdrückt. Durch dieses, der Anwendung entsprechende Meβverfahren ergibt sich für den Anwender eine besser
verwertbare Gröβe. Diese Lochblendenmessung ist gekennzeichnet durch den Eintrag „E 7800“, der an die
Typenbezeichnung angehängt ist.
An aperture is used in front of the component for measurement of the radiant intensity and the half angle (diameter
of the aperture: 2.0 mm; distance of aperture to case back side: 5.4 mm). This ensures that solely the radiation in
axial direction emitting directly from the chip surface will be evaluated during measurement of the radiant intensity.
Radiation reflected by the bottom plate (stray radiation) will not be evaluated. These reflections impair the projection
of the chip surface by additional optics (e.g. long-range light reflection switches). In respect of the application of the
component, these reflections are generally suppressed by apertures as well. This measuring procedure
corresponding with the application provides more useful values. This aperture measurement is denoted by “E 7800”
added to the type designation.
gemessen bei einem Raumwinkel Ω = 0.01 sr / measured at a solid angle of Ω = 0.01 sr
2)
2)
2)
3)
Bestellnummer
Ordering Code
Q62703Q1087
Q62702P5195
Q62703Q1088
Q62703Q4752
Q62703Q4753
Q62703Q1089
Q62703Q4771
Q62703Q4754
Q62703Q2186
Strahlstärkegruppierung
Radiant intensity grouping
I
> 40
> 40
> 10
10 ... 20
> 16
> 3.15
3.15 ... 10
> 5
1.6 ... 3.2
e
(mW/sr)
2
SFH 480, SFH 481, SFH 482
1)
(
1)
I
F
= 100 mA,
t
p
= 20 ms)

Related parts for SFH 482 M E7800