HPR117VC Murata Power Solutions Inc, HPR117VC Datasheet - Page 3

CONV DC/DC +/-15V +/-25MA DIP

HPR117VC

Manufacturer Part Number
HPR117VC
Description
CONV DC/DC +/-15V +/-25MA DIP
Manufacturer
Murata Power Solutions Inc
Series
HPR1xxVCr
Type
Isolatedr
Datasheet

Specifications of HPR117VC

Number Of Outputs
2
Output
±15V
Power (watts)
1W
Mounting Type
Through Hole
Voltage - Input
13.5 ~ 16.5V
Package / Case
14-DIP Module (300 mil, 13 Leads)
1st Output
15 VDC @ 25mA
2nd Output
-15 VDC @ 25mA
Size / Dimension
0.79" L x 0.53" W x 0.38" H (20.1mm x 13.5mm x 9.7mm)
Power (watts) - Rated
0.75W
Operating Temperature
-40°C ~ 100°C
Efficiency
79%
Output Power
0.38 W
Input Voltage Range
13.5 V to 16.5 V
Input Voltage (nominal)
15 V
Output Voltage (channel 1)
15 V
Output Current (channel 1)
+/- 25 mA
Isolation Voltage
750 V
Package / Case Size
DIP
Product
Isolated
Dc / Dc Converter O/p Type
Dual
No. Of Outputs
2
Input Voltage
13.5V To 16.5V
Power Rating
0.75W
Output Voltage
15V
Output Current
25mA
Output Voltage 2
-15V
Output Current 2
-25mA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1770-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HPR117VC
Manufacturer:
MurataPo
Quantity:
56
www.murata-ps.com
Specifi cations are at T
12.6
12.5
12.4
12.3
12.2
12.1
12.0
600
500
400
300
200
100
90
80
70
60
50
40
30
20
10
5.7
5.5
5.3
5.1
4.9
90
75
60
45
30
15
0
0
0
0
0
0
0
0
Output Current each load (mA)
5
5
20
EFFICIENCY VS LOAD
10
40
% of Rated Load (%)
Output Current (mA)
(±12Vout Models)
VOUT VS LOAD
10
10
LOAD CAPACITANCE vs INPUT RISE TIME
VOUT VS LOAD
(5Vout Models)
LOAD CAPACITANCE vs INPUT RISE TIME
40
20
15
15
80
A
Rise Time of Input Voltage (mS)
Rise Time of Input Voltage (mS)
= +25°C nominal input voltage and nominal load.
60
(5 Vout models)
(12 Vout models)
20
20
120
30
80
25
25
SAFE OPERATING AREA
TYPICAL PERFORMANCE CURVES
30
30
160
100
40
SAFE OPERATING AREA
35
35
SAFE OPERATING AREA
15.9
15.7
15.5
15.3
15.1
14.9
220
200
180
160
140
5.4
5.2
5.0
4.8
4.6
40
40
-30
0
0
45
45
OSCILLATION FREQUENCY VS
Output Current each load (mA)
Output Current each load (mA)
50
50
20
20
0
TEMPERATURE
Temperature (°C)
VOUT VS LOAD
(±5Vout Models)
VOUT VS LOAD
(15Vout Models)
NOTES:
1.) When operated within the SAFE OPERATING AREA as defi ned
2.) For dual output models, total load capacitance is the sum of the
30
40
40
by the above curves, the output voltage of HPR1XXC devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steady-
state value.
capacitances on the plus and minus outputs.
60
60
60
0.75 Watt Single Output DC/DC Converter
60
50
40
30
20
10
0
90
80
80
0
Technical enquiries email: sales@murata-ps.com, tel:
5
12.5
12.4
12.3
12.2
12.1
12.0
16.5
16.0
15.5
15.0
14.5
14.0
13.5
11.9
10
LOAD CAPACITANCE vs INPUT RISE TIME
0
0
2010-10-06 TDC_HPR1XXVC.C01 Page 3 of 4
15
Output Power each load (Watts)
Output Current each load (mA)
Rise Time of Input Voltage (mS)
0.2
(15 Vout models)
20
20
(±15Vout Models)
VOUT VS LOAD
VOUT VS LOAD
(12Vout Models)
0.4
25
SAFE OPERATING AREA
40
HPR1XXVC
30
0.6
35
60
0.8
+1 508 339 3000
40
1.0
80
45
50

Related parts for HPR117VC