LW010A Lineage Power, LW010A Datasheet - Page 13

no-image

LW010A

Manufacturer Part Number
LW010A
Description
CONVERTER DC/DC 5V 10W OUT
Manufacturer
Lineage Power
Series
LW010r
Type
Isolated with UVLOr
Datasheet

Specifications of LW010A

Output
5V
Number Of Outputs
1
Power (watts)
10W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
6-DIP Module
1st Output
5 VDC @ 2A
Size / Dimension
2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm)
Power (watts) - Rated
10W
Operating Temperature
-40°C ~ 105°C
Efficiency
81%
Approvals
CE, CSA, UL, VDE
Output Power
10W
Output Current
2A
Input Voltage
48V
Output Voltage
5V
Screening Level
Industrial
Product Length (mm)
25.4mm
Product Height (mm)
10.16mm
Product Depth (mm)
50.8mm
Mounting Style
Through Hole
Pin Count
6
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LW010A
Quantity:
726
Part Number:
LW010A
Manufacturer:
TYCO
Quantity:
20 000
Part Number:
LW010A48
Manufacturer:
LUCENT
Quantity:
28
Part Number:
LW010A8
Manufacturer:
IR
Quantity:
1 000
Part Number:
LW010A81
Manufacturer:
Lucent
Quantity:
28
Part Number:
LW010A81
Manufacturer:
IR
Quantity:
5 142
Part Number:
LW010A84
Manufacturer:
LINEAGEPOWER
Quantity:
20 000
Part Number:
LW010A91
Manufacturer:
GE
Quantity:
20 000
March 27, 2008
Characteristics Curves
Figure 28. LW010AJ, BK, CL Typical Efficiency vs.
Figure 29. Single-Output Typical Output Voltage for
Figure 30. Single-Output Typical Output Voltage for
Lineage Power
85
80
75
70
65
60
0
1.01
0.99
0.50
0.25
0.99
0.75
0.50
1.0
1.01
Normalized Output Current at T
Step Load Change from 50% to 75% of
I
Step Load Change from 50% to 25% of
I
1.0
O
O
0.1
= I
= I
I
O1
NORMALIZED OUTPUT CURRENT,
O
O
0.2
= I
,
,
max
max
O2
0.3
[(I
O1
+ I
0.4
TIME, t (100 µs/div)
TIME, t (100 µs/div)
O2
)/(I
0.5
O1
,
V
V
V
max
I
I
I
= 75 V
= 48 V
= 36 V
0.6
(continued)
+ I
O2
0.7
,
max
18 Vdc to 36 Vdc or 36 Vdc to 75 Vdc Inputs, 10 W and 15 W
)]
0.8
0.9 1.0
C
= 25 °C
8-1858(C)
8-1857(C)
8-1856(C)
Figure 31. Typical Output Voltage Start-Up when
Figure 32. Typical Output Voltage Start-Up when
1.0
1.0
0
0
1.0
0.0
4.0
2.0
0
Input Voltage Is Applied; I
I
Signal Is applied to Remote On/Off;
I
O
O
,
= 80% of I
max
, V
I
= Nominal Line
O
TIME, t (2 ms/div)
,
TIME, t (1 ms/div)
max
O
= 80% of
8-1807(C).a
8-1806(C)
13