JW030B1-M Lineage Power, JW030B1-M Datasheet - Page 2

no-image

JW030B1-M

Manufacturer Part Number
JW030B1-M
Description
CONVERTER DC/DC 12V 30W OUT
Manufacturer
Lineage Power
Series
JW030r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JW030B1-M

Output
12V
Number Of Outputs
1
Power (watts)
30W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
12 VDC @ 2.5A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
30W
Operating Temperature
-40°C ~ 100°C
Efficiency
83%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JW030B1-M
Manufacturer:
LUCENT
Quantity:
27
Part Number:
JW030B1-M
Manufacturer:
LUCENT
Quantity:
530
36 Vdc to 75 Vdc Inputs; 30 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Input Voltage Continuous
Operating Case Temperature
Storage Temperature
I/O Isolation Voltage:
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-peak
Input Ripple Rejection (120 Hz)
(See Thermal Considerations section.)
(V
(5 Hz to 20 MHz, 12 µH source impedance;
T
Considerations section.)
Continuous
Transient
C
I
= 25 °C; see Figure 20 and Design
= 0 V to 75 V; I
Parameter
Parameter
O
= I
O, max
; see Figure 1.)
Symbol
Symbol
T
T
V
stg
I
C
I, max
I
V
i
2
I
I
t
I
Min
36
Min
–40
–40
Typ
48
25
50
1500
Max
100
500
110
80
Max
1.6
0.2
75
March 26, 2008
Lineage Power
Unit
Vdc
Vdc
°C
°C
mAp-p
V
Unit
Vdc
A
dB
A
2
s