DC025ACL-M Lineage Power, DC025ACL-M Datasheet - Page 13

no-image

DC025ACL-M

Manufacturer Part Number
DC025ACL-M
Description
CONV DC/DC +5/+-15V 25W OUT
Manufacturer
Lineage Power
Series
DC025r
Type
Isolatedr
Datasheet

Specifications of DC025ACL-M

Output
5V, ±15V
Number Of Outputs
3
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
18 ~ 36V
Package / Case
9-DIP Module
1st Output
5 VDC @ 5A
2nd Output
15 VDC @ 830mA
3rd Output
-15 VDC @ 830mA
Size / Dimension
2.80" L x 2.40" W x 0.50" H (71.1mm x 61mm x 12.7mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
82%
Approvals
CSA, UL, VDE
Product
Isolated
Output Power
25 W
Input Voltage Range
18 V to 36 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
0.83 A
Output Voltage (channel 3)
- 15 V
Output Current (channel 3)
0.83 A
Isolation Voltage
500 V
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DC025ACL-M
Manufacturer:
LUCENT
Quantity:
26
Part Number:
DC025ACL-M
Quantity:
292
Part Number:
DC025ACL-M
Manufacturer:
SANREX
Quantity:
20 000
Part Number:
DC025ACL-M
Quantity:
55
April 2009
Thermal Considerations
The 25 W triple output power modules are designed to
operate in a variety of thermal environments. As with
any electronic component, sufficient cooling must be
provided to ensure reliable operation. Heat dissipating
components inside the module are thermally coupled
to the case to enable heat removal by conduction, con-
vection, and radiation to the surrounding environment.
Lineage Power
Note: Dimensions are in millimeters and (inches). Drawing is not to scale.
CONNECTORS TO
LOADS, POWER
SUPPLIES, AND
6.35 (0.25) TALL
DATALOGGER,
101.6
(4.00)
27.9
(1.1)
dc-dc POWER MODULE
MADE IN USA
Figure 22. Thermal Test Setup
203.2 (8.00)
AIRFLOW
27.9
(1.1)
12.7 (0.50)
The thermal data presented is based on measure-
ments taken in a wind tunnel. The test setup shown in
Figure 22 was used to collect data. Actual performance
can vary depending on the particular application
environment.
MEASURE CASE
TEMPERATURE AT
THIS POINT
(2.00)
50.8
18 Vdc to 36 Vdc Input; 25 W
203.2
(8.00)
FLOW
AIR-
9.7 (0.38)
19.1 (0.75)
12.7 (0.50)
WIND TUNNEL WALL
AIR VELOCITY PROBE
AMBIENT TEMPERATURE
THERMOCOUPLE
8-866(C).b
13

Related parts for DC025ACL-M