AXA003A0X-SRZ Lineage Power, AXA003A0X-SRZ Datasheet - Page 12

CONVERT DC/DC 0.75 5.5V @ 3A SMD

AXA003A0X-SRZ

Manufacturer Part Number
AXA003A0X-SRZ
Description
CONVERT DC/DC 0.75 5.5V @ 3A SMD
Manufacturer
Lineage Power
Series
Austin MiniLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXA003A0X-SRZ

Output
0.75 ~ 5.5V
Number Of Outputs
1
Power (watts)
16W
Mounting Type
Surface Mount
Voltage - Input
8.3 ~ 14V
Package / Case
5-SMD Module
1st Output
0.75 ~ 5.5 VDC @ 3A
Size / Dimension
0.80" L x 0.45" W x 0.29" H (20.3mm x 11.4mm x 7.3mm)
Power (watts) - Rated
16.5W
Operating Temperature
-40°C ~ 85°C
Efficiency
91%
Approvals
CSA, EN, UL, VDE
Output Power
17 W
Input Voltage Range
8.3 V to 14 V
Output Voltage (channel 1)
0.75 V to 5.5 V
Output Current (channel 1)
3 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
0.75 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1049-2
CC109101276

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AXA003A0X-SRZ
Manufacturer:
SHARP
Quantity:
7 425
Data Sheet
October 2, 2009
Feature Description
Remote On/Off
Austin MiniLynx
an On/Off pin for remote On/Off operation. Two
On/Off logic options are available in the Austin
MiniLynx
On/Off signal, device code suffix “4”, turns the module
ON during a logic High on the On/Off pin and turns
the module OFF during a logic Low. Negative logic
On/Off signal, no device code suffix, turns the module
OFF during logic High and turns the module ON
during logic Low.
For positive logic modules, the circuit configuration for
using the On/Off pin is shown in Figure 27. The
On/Off pin is an open collector/drain logic input signal
(Von/Off) that is referenced to ground. During a logic-
high (On/Off pin is pulled high internal to the module)
when the transistor Q1 is in the Off state, the power
module is ON. Maximum allowable leakage current of
the transistor when Von/off = V
Applying a logic-low when the transistor Q1 is turned-
On, the power module is OFF. During this state
VOn/Off must be less than 0.3V. When not using
positive logic On/off pin, leave the pin unconnected or
tie to V
Figure 27. Circuit configuration for using positive
logic On/OFF.
For negative logic On/Off devices, the circuit
configuration is shown is Figure 28. The On/Off pin is
pulled high with an external pull-up resistor (typical
R
Off state, logic High is applied to the On/Off pin and
the power module is Off. The minimum On/off voltage
for logic High on the On/Off pin is 2.5 Vdc. To turn
the module ON, logic Low is applied to the On/Off pin
by turning ON Q1. When not using the negative logic
On/Off, leave the pin unconnected or tie to GND.
LINEAGE
I
pull-up
ON/OFF
GND
VIN+
= 68k, +/- 5%). When transistor Q1 is in the
IN.
ON/OFF
TM
V
Q1
POWER
ON/OFF
12V series modules. Positive Logic
+
_
TM
12V SMT power modules feature
R1
R2
IN,max
R3
R4
8.3 – 14Vdc input; 0.75Vdc to 5.5Vdc Output; 3A output current
Q2
is 10µA.
MODULE
PWM Enable
Austin MiniLynx
Q3
CSS
Figure 28. Circuit configuration for using
negative logic On/OFF.
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current
limiting continuously. At the point of current-limit
inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought
back into its specified range. The typical average
output current during hiccup is 3.5A.
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, module operation is disabled. The module will
begin to operate at an input voltage above the
undervoltage lockout turn-on threshold.
Overtemperature Protection
To provide over temperature protection in a fault
condition, the unit relies upon the thermal protection
feature of the controller IC. The unit will shutdown if
the thermal reference point T
exceeds 140
not intended as a guarantee that the unit will survive
temperatures beyond its rating. The module will
automatically restarts after it cools down.
TM
ON/OFF
VIN+
12V SMT Non-isolated Power Modules:
GND
V
Q1
R
I
ON/OFF
o
pull-up
ON/OFF
C (typical), but the thermal shutdown is
+
_
ref2
R1
R2
, (see Figure 31)
MODULE
PWM Enable
Q2
CSS
12

Related parts for AXA003A0X-SRZ