OKY-T/5-W5N-C Murata Power Solutions Inc, OKY-T/5-W5N-C Datasheet
OKY-T/5-W5N-C
Specifications of OKY-T/5-W5N-C
Available stocks
Related parts for OKY-T/5-W5N-C
OKY-T/5-W5N-C Summary of contents
Page 1
... For full details go to www.murata-ps.com/rohs Adjustable Output 3 and 5-Amp DOSA-SMT PoLs PRODUCT OVERVIEW The OKY-T/3 and -T/5 series are miniature non- isolated Point-of-Load (POL) switch mode DC/DC power converters for embedded applications. The module is fully compatible with Distributed-power Open Standards Alliance (DOSA) industry-standard specifi ...
Page 2
... P = Positive Polarity N = Negative Polarity Note: Some model number combinations may not be available. Contact Murata Power Solutions for availability. Model Number Product Code OKY-T/3-W5N-C Y00003 OKY-T/3-W5P-C Y01003 OKY-T/5-W5N-C Y00005 OKY-T/5-W5P-C Y01005 email: sales@murata-ps.com 02 Feb 2010 MDC_OKY-T/3,T/5-W5 Series.A10_long Page Package ➀ Case C72 Pinout ...
Page 3
... REF [8.63] 0.340 [1.52] [12.69] 0.060 0.500 REF [17.52] 0.690 RECOMMENDED PAD LAYOUT email: sales@murata-ps.com 02 Feb 2010 MDC_OKY-T/3,T/5-W5 Series.A10_long Page PIN #1 OKY-T/3, -T/5 Function On/Off Control Ground (Common) Trim +V OUT Third Angle Projection [11.9] 0.47 REF [1.52] 0.06 ...
Page 4
... OKY-T/3-W5N-C: 10,961,200 hours OKY-T/3-W5P-C: 10,830,600 hours OKY-T/5-W5N-C: 9,893,917 hours OKY-T/5-W5P-C: 9,765,731 hours OKY-T/3-W5N-C: 8,398,873 hours OKY-T/3-W5P-C: 8,228,758 hours OKY-T/5-W5N-C: 8,338,304 hours OKY-T/5-W5P-C: 8,170,610 hours -40 to +85 ˚C. with derating (Note 9) -40 to +100 ˚Celsius max., no derating (12) -55 to +125 deg. C. +130 ˚Celsius to 85%/+85 ˚C., non-condensing Physical See Mechanical Specifi ...
Page 5
... Less than 3 ºC. per second Peak Temp. 235-260° C Reflow Zone Soaking Zone time above 217° C 45-75 sec 120 sec max Preheating Zone 240 sec max 90 120 150 180 210 240 270 Time (sec) email: sales@murata-ps.com MDC_OKY-T/3,T/5-W5 Series.A10_long Page 300 ...
Page 6
... BNC connectors or the probe ground should not exceed one half- inch and soldered directly to the test circuit. www.murata-ps.com 02 Feb 2010 OKY T/3, T/5-W5 Series CURRENT PROBE +INPUT C IN -INPUT email: sales@murata-ps.com MDC_OKY-T/3,T/5-W5 Series.A10_long Page ...
Page 7
... Negative polarity devices are on (enabled) when the On/Off pin is left open or brought to within a low voltage (see Specifi cations) with respect to –Vin. The device is off (disabled) when the On/Off is pulled high (see Specifi cations) with respect to –Vin. www.murata-ps.com OKY T/3, T/5-W5 Series email: sales@murata-ps.com 02 Feb 2010 MDC_OKY-T/3,T/5-W5 Series.A10_long Page ...
Page 8
... Install only enough capacitance to achieve noise objectives. Excess external capacitance may cause regulation problems, degraded transient response and possible oscilla- tion or instability. www.murata-ps.com 02 Feb 2010 OKY T/3, T/5-W5 Series email: sales@murata-ps.com MDC_OKY-T/3,T/5-W5 Series.A10_long Page ...
Page 9
... OKY-T/3-W5 PERFORMANCE DATA (Vout = 1.2V) OKY-T/3-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 2. 0.5 1 1.5 2 Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=1.2V, Iout=3A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=1.2V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 10
... OKY-T/3-W5 PERFORMANCE DATA (Vout = 1.5V) OKY-T/3-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 2. 0.5 1 1.5 2 Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=1.5V, Iout=3A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 11
... OKY-T/3-W5 PERFORMANCE DATA (Vout = 1.8V) OKY-T/3-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 2. 0.5 1 1.5 2 Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=1.8V, Iout=3A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=1.8V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 12
... OKY-T/3-W5 PERFORMANCE DATA (Vout = 2.5V) OKY-T/3-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 0.5 1 1.5 2 Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=2.5V, Iout=3A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=2.5V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. ...
Page 13
... OKY-T/3-W5 PERFORMANCE DATA (Vout = 3.3V) On/Off Enable Startup (Vin=5.5V, Vout=3.3V, Iout=3A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=3.3V, Cload=0, Iout=1.5A to 3A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 1A/div. OKY-T/5-W5 PERFORMANCE DATA (Vout = 1V) OKY-T/5-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 ...
Page 14
... OKY-T/5-W5 PERFORMANCE DATA (Vout = 1.2V) OKY-T/5-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 2. Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=1.2V, Iout=5A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=1.2V, Cload=0, Iout=2.5A to 5A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. ...
Page 15
... OKY-T/5-W5 PERFORMANCE DATA (Vout = 1.5V) OKY-T/5-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 2. Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=1.5V, Iout=5A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=1.5V, Cload=0, Iout=2.5A to 5A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. ...
Page 16
... OKY-T/5-W5 PERFORMANCE DATA (Vout = 1.8V) OKY-T/5-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 2. Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=1.8V, Iout=5A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=1.8V, Cload=0, Iout=2.5A to 5A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. ...
Page 17
... OKY-T/5-W5 PERFORMANCE DATA (Vout = 2.5V) OKY-T/5-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=2.5V, Iout=5A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=2.5V, Cload=0, Iout=2.5A to 5A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. ...
Page 18
... OKY-T/5-W5 PERFORMANCE DATA (Vout = 3.3V) OKY-T/5-W5 Effi ciency vs. Line Voltage and Load Current @ 25°C (V 100 5. 3. Load Current (Amps) On/Off Enable Startup (Vin=5.5V, Vout=3.3V, Iout=5A, Cload=0) Trace 4=Enable, Trace2=Vout Step Load Transient Response (Vin=5V, Vout=3.3V, Cload=0, Iout=2.5A to 5A) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 2A/div. ...
Page 19
... Angles ± 1˚ Components are shown for reference only. 101.6 4.00 (CORE) 330.2 13.00 REEL INFORMATION (400 UNITS PER REEL) email: sales@murata-ps.com 02 Feb 2010 MDC_OKY-T/3,T/5-W5 Series.A10_long Page 6.86 0.270 Third Angle Projection 44.0 1.73 REF 13.00 .512 ...
Page 20
... The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. www.murata-ps.com/locations 02 Feb 2010 OKY T/3, T/5-W5 Series © 2010 Murata Power Solutions, Inc. email: sales@murata-ps.com MDC_OKY-T/3,T/5-W5 Series.A10_long Page ...