CPD250-4530 POWER ONE, CPD250-4530 Datasheet - Page 5

PWR SUP 250W 3.3/5/12/-12V QUAD

CPD250-4530

Manufacturer Part Number
CPD250-4530
Description
PWR SUP 250W 3.3/5/12/-12V QUAD
Manufacturer
POWER ONE
Series
CPDr
Type
Isolatedr
Datasheet

Specifications of CPD250-4530

Output
5V, 3.3V, ±12V
Number Of Outputs
4
Power (watts)
250W
Mounting Type
Compact PCI®
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 40A
2nd Output
3.3 VDC @ 40A
3rd Output
12 VDC @ 5.5A
4th Output
-12 VDC @ 2A
Size / Dimension
6.40" L x 1.60" W x 5.07" H (162.5mm x 40.6mm x 128.7mm)
Power (watts) - Rated
250W
Efficiency
82.2%
Approvals
CE, CSA, cUL, EN, TUV, UL
Input Voltage
48V
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Not Compliant
Other names
179-2264
Table 2b: Input data of CPA models
Electrical Input Data
General Conditions:
T
Table 2a: Input data of CPD models
BCD20005-G Rev. AF, 18-Aug-10
Input
Characteristics
V
V
V
V
I
I
I
P
P
C
f
t
t
t
Input
Characteristics
V
V
V
I
I
I
P
P
C
f
t
t
t
A
i
i max
inr p
switch
switch
i
i max
inr p
h
bo
su
1
2
3
4
5
h
bo
su
i
i op
i nom
i abs
i0
i inh
i
i nom
i abs
i0
i inh
i
i
= 25 °C, unless T
Rated input frequency: 50 – 60 Hz, operating input frequency range: 47 – 63 Hz
First value for CPD/CPA200, 2
First value for CPA500, 2
Short interruption of V
CPA200/250 with version V117 or higher, as they are equipped with an input voltage trigger
Rated input voltage range
Operating input voltage
Nom. input voltage
Input voltage limits
Typical input current
Max. input current
Peak inrush current
No-load input power
Input power, when inhibited V
Input capacitance
Switching frequency
Hold-up time
Brown-out time
Start-up time
Power factor
Operating input voltage
Nom. input voltage
Input voltage limits
Typical input current
Max. input current
Peak inrush current
No-load input power
Input power, when inhibited V
Input capacitance
Switching frequency
Hold-up time
Brown-out time
Start-up time
C
®
is specified.
4
4
i
without affecting the outputs
nd
value for CPA550
200 – 550 Watt CompactPCI
nd
value for CPD/CPA250
I
T
50 – 60 Hz
without damage
V
V
V
V
I
V
V
V
V
V
without damage
Conditions
Conditions
I
T
V
V
V
V
V
V
V
V
V
V
o
o
o
C min
i nom
i min
i max
i min
i min
i nom
i min
i nom
i nom
i nom
C min
i nom
i min
i max
i min
i nom
i max
i min
i nom
i min
i nom
i nom
= 0 – I
= 0
= 0 – I
, I
, I
, I
, I
– V
, I
, I
, I
– V
, I
, I
, I
, I
, I
, I
– V
, I
, I
, I
– T
– T
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o nom
o
0 V, I
0 V, I
o
o
o max
i max
o max
i max
i max
= 0
C max
C max
= 0
= 0
1
o nom
o nom
0.95
min
100
min
90
0
20
36
Page 5 of 19
0
4
4
5
CPD200/250
CPA200/250
2.9/3.6
1.1/1.4
5.1/6.3
7.0/8.7
1360
230
135
150
135
150
typ
typ
23
48
14
18
27
1
2
2
2
2
®
7.6/9.5
3.2 /4.0
max
max
200
240
264
280
AC-DC and DC-DC Converters
3.2
3.2
75
80
12
30
15
30
CPA, CPD Series Data Sheet
2
2
36
min
0
0.95
min
100
5
5
90
20
0
CPA500/550
2.8/3.1
7.1/7.8
CPD500
12.5
28.6
27.5
230
135
150
135
typ
typ
26
48
17
28
15
4
3
3
1500
max
17.5
www.power-one.com
max
9.4
75
80
25
31
240
264
280
3.2
20
32
VAC
W/VA
VDC
Unit
Unit
kHz
kHz
ms
ms
µF
µF
W
W
A
A
1

Related parts for CPD250-4530