MCP355XDV-MS1 Microchip Technology, MCP355XDV-MS1 Datasheet - Page 22

BOARD DEV SENSOR APP MCP355X

MCP355XDV-MS1

Manufacturer Part Number
MCP355XDV-MS1
Description
BOARD DEV SENSOR APP MCP355X
Manufacturer
Microchip Technology
Datasheets

Specifications of MCP355XDV-MS1

Number Of Adc's
1
Number Of Bits
22
Data Interface
Serial
Inputs Per Adc
1 Differential
Input Range
±0.3 V
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Utilized Ic / Part
MCP355x
Processor To Be Evaluated
MCP355x
Interface Type
RS-232, USB
Lead Free Status / RoHS Status
Not applicable / Not applicable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Not applicable / Not applicable

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP355XDV-MS1
Manufacturer:
MICROCHIP
Quantity:
12 000
MCP3550/1/3
5.2
During Shutdown mode, on the falling edge of CS, the
conversion process begins. During this process, the
internal oscillator clocks the delta-sigma modulator and
the SINC filter until a conversion is complete. This
conversion time is t
Figure
settled completely and there is no latency involved with
the digital SINC filter of the MCP3550/1/3.
The two modes of conversion for the MCP3550/1/3
devices are Single Conversion and Continuous
Conversion. In Single Conversion mode, a consecutive
conversion will not automatically begin. Instead, after a
single conversion is complete and the SINC filter have
settled, the device puts the data into the output register
and enters shutdown.
FIGURE 5-2:
FIGURE 5-3:
DS21950E-page 22
SCK (opt)
SDO/RDY
SDO/RDY
SCK (opt)
Int. Osc
Int. Osc
5-2. At the end of t
CS
Controlling Internal Conversions
and the Internal Oscillator
CS
t
CONV
CONV
Single Conversion Mode.
Continuous Conversion Mode.
t
CONV
and the timing is shown in
CONV
, the digital filter has
t
Hi-Z
CONV
Sleep
t
CONV
In Continuous Conversion mode, a consecutive
conversion will be automatic. In this mode, the device
is continuously converting, independent of the serial
interface. The most recent conversion data will always
be available in the Output register.
When the device exits Shutdown, there is an internal
power-up delay that must be observed.
x24
x24
© 2009 Microchip Technology Inc.
Hi-Z
Shutdown
Shutdown
Hi-Z

Related parts for MCP355XDV-MS1