KITMPL115A2I2C Freescale Semiconductor, KITMPL115A2I2C Datasheet - Page 2

KIT EVALUATION FOR PL115A2I2C

KITMPL115A2I2C

Manufacturer Part Number
KITMPL115A2I2C
Description
KIT EVALUATION FOR PL115A2I2C
Manufacturer
Freescale Semiconductor

Specifications of KITMPL115A2I2C

Sensor Type
Pressure
Sensing Range
50 ~ 115 kPa
Interface
I²C
Voltage - Supply
2.375 V ~ 5.5 V
Embedded
No
Utilized Ic / Part
PL115A2I2C
Interface Type
SPI, I2C
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Operating Current
1 uA
Operating Voltage
2.375 V to 5.5 V
Silicon Manufacturer
Freescale
Silicon Core Number
MPL115A2
Kit Application Type
Sensing - Pressure
Application Sub Type
Pressure Sensor
Kit Contents
Board, Docs
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Sensitivity
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
MPL115A1

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KITMPL115A2I2C
Manufacturer:
Freescale Semiconductor
Quantity:
135
MPL115A2
2
Maximum Ratings
Operating Characteristics
(V
Pressure Sensor
Temperature Sensor
I
I
I
MPL115A2 uses 7-bit addressing, does not acknowledge the general call address 0000000. Slave address has been set to 0x60 or 1100000.
2
2
2
Ref
C I/O Stages: SCL, SDA
C Outputs: SDA
C Addressing
DD
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
Pressure
= 2.375 V to 5.5 V, T
Voltage (with respect to GND unless otherwise noted)
V
SCLK, CS, D
Operating Temperature Range .................................................................................... -40°C to +105°C
Storage Temperature Range........................................................................................ -40°C to +125°C
Overpressure ............................................................................................................... 1000 kPa
Operating Supply Voltage
Supply Current
Range
Resolution
Accuracy
Power Supply Rejection
Conversion Time
(Start Pressure Convert)
Range
Conversion Time
(Start Temperature Convert)
Conversion Time
(Start Both Convert)
Resolution
SCL Clock Frequency
Low Level Input Voltage
High Level Input Voltage
Data Setup Time
DD
.............................................................................................................................. -0.3 V to +5.5 V
Parameters
IN
, D
A
OUT
= -40°C to +105°C, unless otherwise noted. Typical values are at V+ = 3.3 V, T
................................................................................................. -0.3 V to V
Symbol
V
f
VIH
VIL
I
tcp
tcb
t
SCL
tct
DD
SU
DD
Shutdown (SHDN = GND)
Standby
Average – at one measurement per second
-20ºC to 85ºC
Typical operating circuit at DC
100 mV p-p 217 Hz square wave plus 100 mV
pseudo random noise with 10 MHz bandwidth.
Time between start convert command and data
available in the Pressure register
Time between start convert command and data
available in the Temperature register
Time between start convert command and data
available in the Pressure and Temperature
registers
Temperature ADC is 472 counts at 25ºC
Setup time from command receipt to ready to
transmit
Conditions
0.7V DD
2.375
Min
100
-40
50
A
= +25°C.
-5.35
0.15
Freescale Semiconductor
Typ
3.3
3.5
0.1
0.1
0.6
0.6
0.8
DD
±1
5
+0.3 V
0.3V DD
Max
115
105
400
5.5
0.7
0.7
10
1
6
1
counts/ºC
Sensors
kPa/V
Units
KHz
kPa
kPa
kPa
kPa
ms
ms
ms
μA
μA
μA
ºC
ns
V
V
V

Related parts for KITMPL115A2I2C