HMR2300-D21-232-DEMO Honeywell Microelectronics & Precision Sensors, HMR2300-D21-232-DEMO Datasheet - Page 7

KIT DEVELOP MAGNETOMETER RS232

HMR2300-D21-232-DEMO

Manufacturer Part Number
HMR2300-D21-232-DEMO
Description
KIT DEVELOP MAGNETOMETER RS232
Manufacturer
Honeywell Microelectronics & Precision Sensors
Datasheet

Specifications of HMR2300-D21-232-DEMO

Rohs Status
RoHS non-compliant
Sensor Type
Magnetic, Magnetometer
Sensing Range
±2g
Interface
RS-232
Sensitivity
67 microgauss
Voltage - Supply
6.5 V ~ 15 V
Embedded
No
Utilized Ic / Part
HMR2300
Silicon Manufacturer
Honeywell
Application Sub Type
Accelerometer - Three-Axis
Kit Application Type
Sensing - Motion / Vibration / Shock
Silicon Core Number
HMR2300
Kit Contents
Board
Supply Voltage
15V
Lead Free Status / RoHS Status
Other names
342-1012
HMR2300-DEMO-232
HMR2300
COMMAND INPUTS
A simple command set is used to communicate with the HMR2300. These commands can be automated; or typed in real-
time while running communication software programs, such a windows hyperterminal.
(1) All inputs must be followed by a <cr> carriage return, or Enter, key. Either upper or lower case letters may be used. The device ID
(dd) is a decimal number between 00 and 99. Device ID = 99 is a global address for all units.
(2) The “¬” symbol is a carriage return (hex 0D). The “_” sign is a space (hex 20). The output response will be delayed from the end of
the carriage return of the input string by 2 msec (typ.), unless the command sent as a global device ID = 99.
www.honeywell.com
Format
Output
Sample Rate
Set/Reset
Mode
Set/Reset
Pulse
Device ID
Baud Rate
Zero Reading
Average
Readings
Re-Enter
Response
Query Setup
Default Settings
Restore Settings
Serial Number
Software Version
Hardware
Version
Write Enable
Store
Parameters
Too Many
Characters
Missing WE
Entry
Command
*ddWE *ddA
*ddWE *ddB
*ddWE *ddR=nnn
*ddWE *ddTN
*ddWE *ddTF
*ddWE *ddT
*ddWE *ddID=nn
*99WE *99!BR=S
*99WE *99!BR=F
*ddWE *ddZN
*ddWE *ddZF
*ddWE *ddZR
*ddWE *ddVN
*ddWE *ddVF
*ddWE *ddV
*ddWE *ddY
*ddWE *ddN
*ddWE *ddD
*ddWE *ddRST
*ddWE
*ddWE *ddSP
Wrong Entry
Write Enable Off
Inputs
*ddP
*ddC
Esc
*dd]S
*dd]R
*dd]
*99ID=
*ddQ
*dd#
*ddF
*ddH
(1)
ASCII_ON¬
BINARY_ON¬
{x, y, z reading}
{x, y, z stream}
{stream stops}
OK¬
S/R_ON¬
S/R_OFF¬
{Toggle}
SET¬
RST¬
{Toggle}
ID=_nn¬
OK¬
OK¬
BAUD_9600¬
OK¬
BAUD=_19,200¬
ZERO_ON¬
ZERO_OFF¬
{Toggle}
AVG_ON¬
AVG_OFF¬
{Toggle}
OK¬
OK¬
{See Desc.}
OK¬
BAUD=_9600¬
OK¬
BAUD=_9600¬
or
BAUD=_19,200¬
SER#_nnnn¬
S/W_vers:_
nnnn¬
H/W_vers:_
nnnn¬
OK¬
DONE¬
OK¬
Re-enter¬
WE_OFF¬
Response
(2)
Bytes
7 or 28
7 or 8
8 or 9
7 or 8
62-72
10
14
14
14
14
16
22
27
19
...
9
0
7
8
4
4
4
7
3
8
9
7
8
3
3
3
8
7
3
9
(3)
This error response indicates that this instruction requires
ASCII – Output Readings in BCD ASCII Format (Default)
Binary – Output Readings in Signed 16-bit Bianary
Format
P = Polled – Output a Single Sample (Default)
C = Continuous – Output Readings at Sample Rate
Escape Key – Stops Continuous Readings
Set Sample Rate to nnn Where:
Nnn = 10, 20, 25, 30, 40, 50, 60, 100, 123, or 154
Samples/sec (Default = 20)
S/R Mode: TN – ON = Auto S/R Pulses (Default)
*ddT Toggles Command (Default = On)
] Character – Single S/R: ]S -> SET = Set Pulse
Toggle Alternates Between Set and Reset Pulse
Read Device ID (Default = 00)
Set Device ID Where nn = 00 to 98
Set Baud Rate to 9600 bps (Default)
Set Baud Rate to 19,200 bps
Zero Reading Will Store and Use Current as a Negative
Offset so That the Output Reads Zero Field
*ddZR Toggles Command
The Average Reading for the Current Sample X(N) is:
Xavg=X(N)/2 + X(N-1)/4 + X(N-2)/8 + X(N-3)/16 + ...
*ddV Toggles Command
Turn the “Re-Enter” Error Response ON (*ddY) or OFF
(*ddN). OFF is Recommended for RS-485 (Default = ON)
Read Setup Parameters. Default: ASCII, POLLED, S/R
ON, ZERO OFF, AVG OFF, R ON, ID=00, 20 sps
Change All Command Parameter Settings to Factory
Default Values
Change All Command Parameter Settings to the Last
User Stored Values in the EEPROM
Output the HMR2300 Serial Number
Output the HMR2300 Software Version Number
Output the HMR2300 Hardware Version Number
Activate a Write Enable. This is required before
commands: Set Device ID, Baud Rate, and Store
Parameters.
This writes all parameter settings to EEPROM. These
values will be automatically restored upon power-up.
A command was not entered properly or 10 characters
were typed after an asterisk (*) and before a <cr>.
a write enable command immediately before it.
TF – OFF = Manual S/R Pulses
(8 bits, no parity, 1 stop bit)
Description
]R -> RST = Reset Pulse
7