24
(b) Connection of emulation probe GND wire
There are 2 GND wires in the emulation probe. Connect them to the QB-179F124 and target system.
<1> Fasten the GND wire on the QB-179F124 side of the emulation probe to the nut on the bottom of the
<2> Next plug the connector on top of the emulation probe into the connector at the opening on the bottom of
<3> Connect the exchange adapter and emulation probe to the target connector.
<4> Connect the GND wire on the target system side of the emulation probe to the target system GND.
QB-179F124 using a #0 or #1 Phillips precision driver (connection of B to A in Figure 2-6).
the QB-179F124 from below being careful of the insertion direction.
pin or screw is fastened to the target system GND, remove the transparent terminal cover on the end of
the GND wire and fasten the Y terminal of the GND wire to the target system (C in Figure 2-6).
GND on the target system is an exposed pad, likewise fasten the Y terminal to the pad on the target
system by soldering (recommended soldering iron temperature setting:
C
Target system
CHAPTER
Preliminary User’s Manual
Figure 2-6. GND Wire
2
SETUP
U18586EJ1V0UM
PROCEDURE
300°C).