8536700000 Weidmuller, 8536700000 Datasheet

no-image

8536700000

Manufacturer Part Number
8536700000
Description
PRC
Manufacturer
Weidmuller
Series
PRCr
Datasheets

Specifications of 8536700000

Accessory Type
Clip, Hold Down
For Use With/related Products
PRZ/PRS Series
For Use With
8552440000 - COUPLER RELAY 24VDC 2C0 DPDT AU8575950000 - COUPLER RELAY 230VAC 2CO DPDT AU8530720000 - COUPLER RELAY 120VAC LD 2CO DPDT8530710000 - COUPLER RELAY 120VAC LD 1CO SPDT8575940000 - COUPLER RELAY 120VAC 2CO DPDT AU8536630000 - COUPLER RELAY 115VDC LD 2CO DPDT8536610000 - COUPLER RELAY 115VDC LD 1CO SPDT8561760000 - COUPLER RELAY 24VDC LD 2CO DPDT8596000000 - COUPLER RELAY 24VDC 2 C0 DPDT AU8536560000 - COUPLER RELAY 24VAC LD 2CO DPDT8536530000 - COUPLER RELAY 24VAC LD 1CO SPDT8595990000 - COUPLER RELAY 230VAC 2CO DPDT AU8595960000 - COUPLER RELAY 120VAC 2CO DPDT AU8536520000 - COUPLER RELAY 115VDC LD DPDT8536510000 - COUPLER RELAY 115VDC LD SPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Relay Coupler
58

Related parts for 8536700000

8536700000 Summary of contents

Page 1

Relay Coupler 58 ...

Page 2

Relay Coupler The universal foot of the Weidmüller relay modules allow them to be assembled 7.5 and mounting rails in accordance with European standards EN 50 035 and EN 50 ...

Page 3

... Relay couplers with plugged relays Relay couplers with plugged relays are only conditionally suitable for use in appli- cations subject to heavy vibrations. Relay couplers with soldered relays are to be preferred. Derating curves The contact resistance is largely responsi- ble for heat development within the relay. ...

Page 4

... EN 50 178 or DIN VDE 0106 Part 101. As more and more users employ only equipment that guarantees "protec- tive separation", a lot of manufacturers of relays refer to DIN VDE 0106 and test their products accordingly. Consequently, the quoted values correspond to the require- ments for "protective separation". ...

Page 5

... EG 7 relay couplers can be optionally mounted onto rails. The RST EG 7 locking socket is also avail- able for use with the pluggable relays cou- plers. The enclosed EG 7 housing are equipped with clamping yoke screw connections. The following conductor cross-sections can be connected: NO/NC: 0 ...

Page 6

... Types of Housings for Relay Coupler Weidmüller RS locking socket Locking sockets with relays RS 30, 31, 32 are either 11 wide depending on version. The open profile makes the use of pluggable relays possible. Modules mounted onto the locking sock- ets are provided with clamping yoke screw connections or push-on connectors for wiring conductors ...

Page 7

Relay Coupler Electromechanical switching Output 24 V Housing EG 0133660000 Page 72 0536260000 Page 72 WAVESERIES WRS EG 7* 8216520000 8147120000 8092340000 Page 80 PLUGSERIES PRS / PRZ RS 30 1101661001 1101611001 1101621001 1101761001 1101711001 1101721001 Page ...

Page 8

Relay Coupler Electromechanical switching Output 48 V Housing EG 0662660000 0662460000 Page 72 Page 72 WAVESERIES WRS EG 7* 8092370000 8092380000 Page 81 Page 1101861001 1101161001 1101811001 1101111001 1101821001 1101121001 1101961001 1101261001 1101911001 1101211001 1101921001 1101221001 Page ...

Page 9

Relay Coupler Electromechanical switching Output 230 V Housing EG 0543860000 Page 72 WAVESERIES WRS EG 7* 8092460000 8178200000 Page 81 PLUGSERIES PRS / PRZ RS 30 1102261001 1102211001 1102221001 Page RSM MCZ R MICROSERIES MRS ...

Page 10

Relay Coupler Electromechanical switching Output 12 V Housing EG WAVESERIES WRS EG 7* 8092310000 8092320000 Page 80 Page 80 PLUGSERIES PRS / PRZ RS 30 1129421001 1129521001 Page 91 Page DKR 35 8171100000 Page 70 MICROSERIES MRS ...

Page 11

... Insulation coord.- and voltage proof, input/output mounting rail Ambient temperature Storage temperature Conductor Conductor cross-section Approvals Overall width Accessories End plate Further accessories, dimensions and connection data see 68 MCZ R 24 Vdc MCZ R 24 Vdc/Au Limit diagram U/Vdc 300 prohibited area 200 ...

Page 12

Relay Couplers in Component Housings MCZ R 110 Vdc MCZ R 120 Vac Limit diagram U/Vdc 300 prohibited area 200 100 Type Cat. No. Type Cat. No. MCZ R 110 Vdc 8467470000 MCZ ...

Page 13

... Pollution severity Clearances and creepage distances Operating temperature without clearance with clearance Storage temperature Conductor Conductor cross-section Overall width Accessories End plate Further accessories, dimensions and connection data see 70 DKR 5 Vdc DKR 12 Vdc Type Cat. No. Type Y DKR 5 Vdc 8019600000 W DKR 5 Vdc ...

Page 14

Relay Couplers in Component Housings Mini coupler DKR DKR 24 Vac/dc DK5R-1U Type Cat. No. Type Cat. No. DKR 24 Vdc 8215620000 DK5R-1U 9454910000 Input: top Input: bottom 24 Vdc ± Vac/dc ± mAac/7 ...

Page 15

... Storage temperature Ambient temperature –, mounted on rail without clearance –, mounted on rail with clearance ≥ Approvals Insulation coordination acc 50178 Overvoltage category Pollution severity Accessories, dimensions and connection data see ** Larger values on request 72 EGR EG 2 EGR Direct and alternating voltage AC/DC voltage Type Cat ...

Page 16

... Status indicator Storage temperature Ambient temperature –, mounted on rail without clearance –, mounted on rail with clearance ≥ Insulation coordination acc 50178 Overvoltage category Pollution severity Accessories, dimensions and connection data see ** Larger values on request EGR voltage 2 changeover contacts LED is parallel to coil and ...

Page 17

... Pollution severity Implemented clearance and creepage path Insulation and voltage strength Insulation and voltage strength of entire circuit to mounting rail Testing Input/output high voltage test Accessories, dimensions and connection data see * at ambient temperature 20°C 74 WRS 1 2.4-24 VDC WRS 1 24 VDC Type Cat. No. ...

Page 18

WAVESERIES Relay Coupler in Component Housings WRS 1 24/115 VUC WRS 1 24 VUC 230 VAC Type Cat. No. Type Cat. No. WRS 1 24/115 Vuc WRS 1 24 Vuc/230 Vac 8418220000 8418230000 WRZ 1 8430210000 WRZ 1 8430220000 24 ...

Page 19

... Pollution severity Implemented clearance and creepage path Insulation and voltage strength Insulation and voltage strength of entire circuit to mounting rail Testing Input/output high voltage test Accessories, dimensions and connection data see * at ambient temperature 20°C 76 WRS 2 12/24 VDC WRS 2 24/48 VUC 100 Schematic circuit diagram ...

Page 20

... Implemented clearance and creepage path Insulation and voltage strength Insulation and voltage strength of entire circuit to mounting rail Testing Input/output high voltage test Accessories, dimensions and connection data see * at ambient temperature 20°C WRS 2 12/24 VDC WRS 2 24/48 VUC 100 Schematic circuit diagram ...

Page 21

... Pollution severity Implemented clearance and creepage path Insulation and voltage strength Insulation and voltage strength of entire circuit to mounting rail Testing Input/output high voltage test Accessories, dimensions and connection data see * at ambient temperature 20°C 78 WRS 2 12/24 VDC WRS 2 24/48 VUC 100 Schematic circuit diagram 100 Abstand> ...

Page 22

... Implemented clearance and creepage path Insulation and voltage strength Insulation and voltage strength of entire circuit to mounting rail Testing Input/output high voltage test Accessories, dimensions and connection data see * at ambient temperature 20°C WRS 2 24 VUC WRS 2 230 VAC 100 Schematic circuit diagram ...

Page 23

... Insulation coordination acc 50178 Safe isolation according to VDE 0106 part 101 Rated impulse voltage Clearances and creepage distances Overvoltage category Pollution severity Accessories Cross-connection comb. 16fold Accessories, dimensions and connection data see 1) Serves only as a spare part for NO and NC 80 EGR EG 7 RST EGR V– ...

Page 24

Relay Couplers in Components Housings EG 7 EGR Type Cat. No. Type Cat. No. EGR EG7 8092370000 EGR EG7 8092400000 EGR EG7 8092380000 EGR EG7 8092410000 1) EGR EG7 8092390000 EGR EG7 8092420000 RST ...

Page 25

... Rated cross-section 0.5 mm 0.5...2.5mm Flammability V0 Relay type Schrack RT1 / RT2 Dimensions WxHxT 15 Approvals CE, UL recognized, cUL Rail mounted TS 35 Accessories Cross-connection 2-pole black ZQV 2.5N/4-2 SW1784270000 60 2-pole red ZQV 2.5N/4-2 RT 1784280000 60 2-pole blue ZQV 2.5N/4-2 BL 1784290000 60 Marking tags WS 10/5 WS 15/5 Qty ...

Page 26

... PXZ35 8536691001 16 A 250 V > 2 -40°C ... +60°C V0 Type Cat. No. PRC 8536700000 PLED 24 Vdc 8536710000 PLED 24 Vdc red 8611010000 PLED 48 Vdc 8536720000 PLED 115 Vdc 8536730000 PLED 24 Vac 8536750000 PLED 120 Vac 8536760000 PLED 230 Vac 8536780000 PLED 230 Vac red 8611000000 PLRC 200 nF/200Ω ...

Page 27

... PLUGSERIES Relays on Sockets Pluggable relay types Print figure/circuit diagram Relay type RT/SGR 84 1 changeover contact 2 changeover contacts Pluggable relay 12 Vdc 1 changeover contact 12 Vdc 2 changeover contacts 24 Vdc 1 changeover contact 24 Vdc 1 changeover contact AU 24 Vdc 2 changeover contacts 24 Vdc 2 changeover contacts AU 48 Vdc 1 changeover contact ...

Page 28

... Vac 4 kVA 10 mA /100 mW 500 typ. 10/3 ms typ. 0.5 > switching operations -25°C ... +70° SEV, UL, CSA, DEMKO, VDE, PTB RP 3SL Relays for high switching currents Type Schrack RP 3SL Cat. No RP3SL 24 Vdc 1NO 8588510000 1 normally-open contact AgSnO 120 250 V 4 kVA 500 typ ...

Page 29

Relay Couplers on Sockets MICROSERIES in Terminal Format MICRO RELAY MRS/MRZ This module can be used as a universal interface between the controller and actuator for switching small to medium-sized loads. Pluggable cross-connection in the input and output reduces wiring ...

Page 30

Relay Couplers on Sockets MICROSERIES in Terminal Format MRS 24 Vdc 1CO MRS 24 Vuc 1CO MRZ 24 Vdc 1CO MRZ 24 Vuc 1CO Type Cat. No. Type Cat. No. MRS 24 Vdc 1CO 8533640000 MRS 24 Vuc 1CO8556050000 MRZ ...

Page 31

... Relay Couplers on Sockets MICROSERIES in Terminal Format Accessories General technical data Clampable conductor: Solid H07V-U Fsolid H07V-K „f“ with ferrules acc. to DIN 46 228/1* „f“ with ferrules with plastic collar* 2 Max. clampable range in mm /gauge pin acc. to IEC 60 947-1 Size Rated torque ...

Page 32

... Relay Couplers on Sockets MICROSERIES in Terminal Format Accessories Contact service life Material AgSnO 2 acc. to Pluggable relay Coil voltage changeover contact Coil voltage changeover contact Coil voltage changeover contact Coil voltage changeover contact Coil voltage changeover contact Coil voltage changeover contact, 5 µAU Coil voltage changeover contact, 5 µAU ...

Page 33

Relay Couplers on Sockets NC changeover contact Schematic circuit diagram Rated data Input voltage 5…60 V ± 10%; 115 V/230 – 15% Rated consumption – (W) Rated consumption ~ (VA) ...

Page 34

Relay Couplers on Sockets Screw connection Screw connection changeover contact Ordering data Screw connection (LP) Connection method 1 2 Schematic circuit diagram NO NO Contact Input Function ...

Page 35

Relay Couplers on Sockets changeover contact Usable for high switching-power Suitable for switching inductive loads Schematic circuit diagram Ordering data Rated data Input voltage Rated consumption – (W) Rated consumption – (VA) Drop-out current of the relay ...

Page 36

Relay Coupler on Locking Socket Profile with power contacts Type Cat. No. RS 31, 230 V~ 1128461001 RS 31, 230 V~ 1128431001 RS 31, 230 V~ 1128411001 230 V –15 % – ...

Page 37

Relay Couplers on Sockets RS 32 with 2 changeover contacts Schematic circuit diagram Ordering data Rated data Input voltage Rated consumption – (W) Rated consumption ~ (VA) Drop-out current of the relay** (at 20 °C) Drop-out current of the relay** ...

Page 38

Relay Couplers on Sockets Type Cat. No. Type Cat. No 9406421001 RS 32 9406521001 48 V0, ± V–, ±10 % 0.6 W 0.6 W 0.9 VA – 48 V– 1.5 ...

Page 39

... V– AgNi 90/10 48 V– AgNi 90/10 48 V– AgNi 90/10 115 V– AgNi 90/10 115 V– AgNi 90/10 115 V– RSM relays, soldered RSM relays, plug-in 115 V~ 115 V0 230 V~ 230 V0 – – – – – – – – 0.6 VA 0.6 VA ...

Page 40

... Common negative potential, positive is switched 2 ) Common negative potential, negative is switched RSM 4 R/RS RSM 8 R/RS RSM 16 R/RS Positve Negative 1 4 relays 8 relays 16 relays switching ) switching 3 ) Approval by the Germanischer Lloyd 4 ) Empty modules without relays AC-DC/DC voltage Relay Relay Relay Mounted 2 ) pluggable pluggable soldered width – 1113161001 145 mm ...

Page 41

... changeover contacts changeover cont.) For relays with one socket with pins. The table on page 87 offers an overview of the most important manufacturers of relays in groups 2, 3 and 4. The list is pro- vided for information purposes only, and does not claim to be complete Size 1 Size 2 Size 2 ...

Page 42

... List of Plug-in Relays for Weidmüller Relay Socket Modules Group 1 International relays • changeover contacts • changeover contacts Manufacturer Relay type EBERLE • • ELESTA • • FEME • • GRUNER • • HALLER • • ITT (MTI) • MAT 2 • MAT 4 FUJITSU • ...

Page 43

... Relay Sockets for Industry Relays Rated data Contact data Contact number and type Contact version Contact material Max. braking capacity AC Rated voltage Continuous current Switch-on current Min. contact rating Mechanical service life Response / drop out time Bounce time Test voltage Isolation acc. to IEC664 ...

Page 44

... Connection data Screw connection, solid Screw connection, flexible Conductor cross-section Rated data Coil voltage (types without LED) Contact voltage Contact current Accessories Mounting rail (2 m lenghts) End bracket (thickness mm) Insert tag (blanc)** Protective strip, transparent** Retainer clip for Schrack relays Schrack ...

Page 45

... Connection data Screw connection, solid Screw connection, flexible Conductor cross-section Rated data Coil voltage (types without LED) Contact voltage Contact current Accessories Mounting rail (2 m lenghts) End bracket (thickness mm) Insert tag (blanc)** Protective strip, transparent** Retainer clip for Schrack relays 102 RS 6 ...

Page 46

... Relay Coupler, Relay Sockets Module for Industry Relays 0167161001 Plug-in relay for Plug-in relay for Octal socket submagnal socket 8-pole 11-pole 2 changeov changeov changeov request 8010061001 on request 0167161001 0188661001 on request 75 0.5…4 mm 0.5…4 mm 0.5… 0.5…2.5 mm 0.5…2.5 mm 0.5…2.5 mm AWG 26… ...

Page 47

Opto-coupler 104 ...

Page 48

... DIN VDE 0884. Double or reinforced insulation for protective separation must be dis- charge proof. High voltage tests, as are usual with relays, cannot be carried out with semi-conductors, because they could lead to the destruction of the semi-con- ductor. Safe separation for the given rated ...

Page 49

Opto-coupler Control side of the opto-coupler interface 3 basic circuits are to be differentiated on the input side of the opto-coupler#s inter- face pure DC input with polarity protec- tion diode wich prevents the opto-cou- pler from ...

Page 50

Opto-coupler Opto-couplers are normally given with an output voltage supply from 5…48 VDC. These values should not be cut or exceed any occasion. The load current should not be higher than the stated max. output current. Continuously exceeding ...

Page 51

Types of housing for opto-coupler Weidmüller coupler modules are enclosed in housings that are appropriate for industrial applications. The housings are suitable for fitting onto mounting rails accordance ...

Page 52

Weidmüller locking socket RS The locking socket with opto-couplers RS 40 have a width of 11.2 mm. The modules on locking socket profiles are equipped with clamping yoke (screw connection) units for conductor connection. Connectable are: solid conductors: 0.5…4 mm ...

Page 53

Opto-coupler Electronic switching Output Housing ≤ 0558160000 Page 122 WAVESERIES WOS 1160961001 1161761001 1177860000 Page 137 RSM DKO 32 8008090000 Page 116 DKO 35 8008150000 Page 116 ...

Page 54

Opto-coupler Electronic switching Output Housing ≤ ≤ 0 8092550000 Page 132 8234590000 Page 132 RS 40 1161061001 Page 137 1161860000 Page 137 DKO 35 8151230000 ...

Page 55

Opto-coupler Electronic switching Output 230 Housing ≤ WAVESERIES WOS DKO 32 8008100000 Page 119 DKO 35 8008160000 Page 119 MCZ O 8421380000 Page 114 230 Vuc/ac 112 5 ...

Page 56

Opto-coupler Electronic switching Output Housing ≤ ≤ 0.1 A EGO 8011250000 0114260000 Page 122 Page 122 WAVESERIES WOS EGO 7 8092510000 8234570000 Page 132 RS 40 1118760000 1161660000 ...

Page 57

... Ambient temperature rowed on mounting rail without clearances Ambient temperature rowed with clearances ≥ Storage temperature Conductor Conductor cross-section Approvals Overall width Accessories End plate Further accessories, dimensions and connection data 114 MCZ O MCZ O 24 Vac/ Vac/ Output current Derating curve rated to ambient temperature a = rowed without clearances on the mounting rail b = rowed with clearances ≥ ...

Page 58

... Ambient temperature rowed with clearances ≥ Storage temperature Conductor Conductor cross-section Approvals Overall width Accessories End plate Further accessories, dimensions and connection data MCZ O MCZ O 24 Vdc/5 VTTL 5 V TTL/5...48 Vdc 1* Derating curve rated to ambient temperature a = rowed on the mounting rail without clearances b = rowed with clearances ≥ ...

Page 59

... Pollution severity Clearances and creepage distances Operating temperature without clearances with clearances Storage temperature Conductor Conductor cross-section Overall width Accessories End plate Further accessories, dimensions and connection data 116 DKO 5 Vdc DKO 5 VTTL Type Cat. No. Type Y DKO 5 Vdc 8018620000 W DKO 5 Vdc ...

Page 60

... Pollution severity Clearances and creepage distances Operating temperature without clearances with clearances Storage temperature Conductor Conductor cross-section Overall width Accessories End plate Further accessories, dimensions and connection data DKO 24 Vdc DKO 24 Vdc Type Cat. No. Type Cat. No DKO 24 Vdc 8028300000 DKO 24 Vdc ...

Page 61

... Pollution severity Clearances and creepage distances Operating temperature without clearances with clearances Storage temperature Conductor Conductor cross-section Overall width Accessories End plate Further accessories, dimensions and connection data 118 DKO 24 Vdc DKO 24 Vdc Mode: Type Cat. No. Type Y W DKO 24 Vdc 8215630000 ...

Page 62

... Clearances and creepage distances Operating temperature without clearances with clearances Storage temperature Conductor Conductor cross-section Overall width Accessories End plate Further accessories, dimensions and connection data DKO DK5 24 Vdc DKO 115 Vac/dc Type Cat. No. Type Cat. No. Y DKO 115 Vac/dc 8027980000 W ...

Page 63

... Voltage drop at max. load Feature of output circuit Indication Dielectric strength input/output Dielectric strength to mounting rail Clearances and creepage distances Operating temperature Storage temperature Conductor Conductor cross-section Overall width Accessories End plate 120 DKO 35 48 Vdc DKO 35 60 Vdc W Type Cat. No. Type Y W ...

Page 64

... Voltage proof input-output/mounting rail -25 °C…+50 °C Operating temperature -40 °C…+60 °C AWG 22…12 Storage temperature 2 0.5…4 mm Conductor 12 mm Conductor cross-section Overall width Type Cat. No. Accessories AP DKT4 0687560000 End plate DKO Schematic circuit diagram Type Cat. No DKO 8164250000 24 Vdc ±20 % ≤ available 300 Hz f ...

Page 65

... Min. input impulse width Storage temperature Ambient temperature –, rowed on mounting rail without clearances –, rowed with clearances ≥ Insulation coordination 178 Overvoltage category Pollution severity Accessories, dimensions and connection data see 122 EGO 1 EGO For low voltage alternatively positive or negative switching ...

Page 66

Opto-coupler in component housing EG EGO Wiring option Type Cat. No. EGO 0609860000 24 V0, ±10 % 0 5…48 V– ) <1.6 V 100 mA 0.8 A/10 ms 0.16 ...

Page 67

... Coordination of insulation according 178 Opto-coupler according to VDE 0884 Rated voltage Rated impulse voltage Overvoltage category Pollution severity Clearance/creepage path Accessories, dimensions and connection data see * at ambient temperature 20 °C/horizontal installation 124 WOS 1 5 VDC WOS 1 3.5-15 VDC WOS 1 12 VUC negative switching Type Cat ...

Page 68

... Reliable separation according 178 Coordination of insulation according 178 Opto-coupler according to VDE 0884 Rated voltage Rated impulse voltage Overvoltage category Pollution severity Clearance/creepage path Accessories, dimensions and connection data see * at ambient temperature 20 °C/horizontal installation WOS 1 115 VUC WOS 1 230 VUC Type Cat. No. Type Cat. No. ...

Page 69

... Reliable separation according 178 Coordination of insulation according 178 Opto-coupler according to VDE 0884 Rated voltage Rated impulse voltage Overvoltage category Pollution severity Clearance/creepage path Accessories, dimensions and connection data see * at ambient temperature 20 °C/horizontal installation 126 WOS 2 24 VUC WOS 2 115 VUC Schematic circuit diagram 70 Type Cat ...

Page 70

... Coordination of insulation according 178 Opto-coupler according to VDE 0884 Rated voltage Rated impulse voltage Overvoltage category Pollution severity Clearance/creepage path Accessories, dimensions and connection data see * at ambient temperature 20 °C/horizontal installation WOS 2 15-60 VUC WOS 2 115 VUC Schematic circuit diagram Zero V. switch Zero V. switch ...

Page 71

... Coordination of insulation according 178 Opto-coupler according to VDE 0884 Rated voltage Rated impulse voltage Overvoltage category Pollution severity Clearance/creepage path Accessories, dimensions and connection data see 1) Protection circuit for output load necessary, page 107 128 WOS 2 24 VUC WOS 2 115 VUC Schematic circuit diagram ...

Page 72

... Reliable separation according 178 Coordination of insulation according 178 Opto-coupler according to VDE 0884 Rated voltage Rated impulse voltage Overvoltage category Pollution severity Clearance/creepage path Accessories, dimensions and connection data see WOS 1 5 VTTL WOS 1 12-28 VDC 50 kHz 100 kHz Schematic circuit diagram 100 Type Cat ...

Page 73

... Storage temperature Ambient temperature - rowed on mounting rail without clearances - rowed with clearances Insulation coordination EN 50 178 Overvoltage category Pollution severity Accessories, dimensions and connection data see 1 ) Error: short-circuit, overload, over- or under voltage at out- put, overtemperature in the module 130 EGO 5 PKR 24 Vac/dc ...

Page 74

... Operating temperature - rowed on mounting rail without clearances - rowed with clearances Insulation coordination 178 Reliable separation Overvoltage category Pollution severity Accessories, dimensions and connection data see OST EG7 2 A • Short circuit protected and over load-safe output OST EG 7 • 3-colour status-LED for ...

Page 75

... Switching frequency Storage temperature Ambient temperature Connection Insulation coordination 178 Protective separation Clearances and creepage distances Rated impulse voltage Overvoltage category Pollution severity Accessories Cross connection comb 16-pole Further accesories, dimensions and connection data see 132 EGO EG 7 OST EGO V– Type Cat ...

Page 76

... Clearances / creepage distances 6 kV Rated impulse voltage III Overvoltage category 2 Pollution severity Type Cat. No. Accessories QB 16/10.16 1650330000 Cross connec. comb 16-pole Page 304 Futher Accessories, dimensions and connection data see EGO EG 7 RC/ OST OST 115 V0 230 V9 Type Cat. No. Type Cat. No. EGO EG7 8397420000 ...

Page 77

... AC (50 Hz) Insulation Test voltage control circuit - switching circuit DC Test voltage control circuit - switching circuit AC Further data Operating temperature range Weight Approvals Celduc Further accessories, dimensions and connection data AC version Type/Version Cat. No. Screw connection POS 24Vac/24Vdc 2.5A 8615600000 POS 24Vac/24Vdc 5A 8615620000 ...

Page 78

... Test voltage control circuit - switching circuit AC/DC Further data Operating temperature range -40 °C…+50 °C Weight approx.11 g Approvals cUL, UL recognized Celduc STD07205 Further accessories, dimen- sions and connection data see page 83 Type Cat. No. Type Cat. No. SSR 24 VUC/230VAC 2A SSR 24 VUC/24VUC 1A 8576370000 8576380000 ...

Page 79

Opto-coupler on locking socket profile RS 40 Opto-couplers for signal input Rated data Input voltage Rated consumption – (W) Rated consumption ~ (VA) Output supply voltage Voltage drop at max. load current Output current Derating curve a = rowed on ...

Page 80

Opto-coupler on locking socket profile Ordering data Connection method Input voltage V– 115 V0 230 V~ 230 V~ Connection data Insulation stripping length Conductor cross-section Dimensions Mounting ...

Page 81

Opto coupler on locking socket with multiple interface RSM (Opto-couplers) Note! During operation and maintenance please observe the relevant ESD measures. (ESD endangered area) Also available as relay coupler, see page 84/85 Schematic circuit diagram Opto coupler 24 Vdc / ...

Page 82

Opto coupler on locking socket with multiple interface RSM RSM Opto couplers DC/negative switching (common positive) Ordering data Conn. method Input RSM 4 OS Input/output voltage w/o. optocoupl. 4 optocoupl. Screw V– ...

Page 83

... Opto coupler, locking socket for semi-conductor relays Single and multiple socket interface- unit Advantages of semiconductor relays: • Wear-free switching also with high switching frequencies • Bounce-free switching • No electomagnetic interferences • High insulation-voltage between load and control circuit Note! The relevant ESD ...

Page 84

... Semi-conductor relays Solid state relays Input module for signal input HRE 24 and output DC/DC Schematic circuit diagram Ordering data Type Cat. No. HRE 24 117440000 Rated data Input voltage 10…32 V– (process) Input current at max. V 21.33 mA Input resistance 1.5 kΩ Switch-on voltage – ...

Page 85

Timers 142 ...

Page 86

... Output of the timing relays The load in every module is switched by a changeover relay (250 V, 8 A). The multifunction module (ITM) switches both changeover relays immediately or, one changeover relay immediately and the other changeover relay delayed. ITTo Load ITR, ITP, ITWo, ITWw, ITTw,ITTT, ITMF ...

Page 87

Functions of the Timers Response delay ITR timer relay As soon as the operating voltage is applied, the preset delay period T begins. After time period T has expired, output R connects the load. Wiping contact timer relay without control ...

Page 88

... IEC529 testers and test procedures • IEC 664 regulations for high-voltage fuses for motor circuits • IEC 801 EMC compatibility • VDE 0110 insulation coordination for low-voltage electrical equipment • VDE 0435 relays with fixed times Connection technology Clamping yoke has the following capacities: 2 • ...

Page 89

Multifunctional Timers • Response delay ITM • Response delay and Multifunctional timer relay turn-off delay • Additive response delay • Wiping contact with control input • Wiping function • Turn-off delay with control input • Pulse generator (begins in the ...

Page 90

Timers Schematic circuit diagram Ordering data Contact Time periods Repeat accuracy (const. parameter) Anzeigegenauigkeit gemäß IEC 1812-1 Input Input voltage Voltage tolerance Duty factor Rated power consumption Min. switch-on time for the supply Min pulse duration type Max. reset time ...

Page 91

Timers Schematic circuit diagram Ordering data Contact Time periods Repeat accuracy (const. parameter) Accuracy of indication acc. to IEC 1812-1 Input Input voltage Voltage tolerance Duty factor Rated power consumption Min pulse duration type Max. reset time at voltage interruption ...

Page 92

Timers Schematic circuit diagram Ordering data Contact Time periods Repeat accuracy (const. parameter) Accuracy of indication acc. to IEC 1812-1 Input Input voltage Voltage tolerance Duty factor Rated power consumption Min pulse duration type Max. reset time at voltage interruption ...

Page 93

Timers Schematic circuit diagram Ordering data Contact Time periods Repeat accuracy (const. parameter) Accuracy of indication acc. to IEC 1812-1 Input Input voltage Voltage tolerance Duty factor Rated power consumption Min pulse duration type Max. reset time at voltage interruption ...

Page 94

... Voltage proof, input/output-TS Operating temperature without clearances with clearances Storage temperature Total width Conductor Conductor cross-section Reverse polarity protection Accessories End plate Dimensions see • Components for extending short pulses • Provides PLC versions with switch-on/off delay • Fixed times DKZ 24 Vac/dc ...

Page 95

... Overvoltage category Pollution severity Clearance and creepage distances Voltage proof, input/output-TS Operating temperature without clearances with clearances Storage temperature Total width Conductor Conductor cross-section Accessories End plate Dimensions see 152 DKZ DK5 DKZ DK5 Type Cat. No. Type Cat. No. DKZ DK5 8228680000 ...

Page 96

... Voltage proof input/output-TS Storage temperature Operating temperature without clearances with clearances Total width Conductor Conductor cross-section Accessories End plate Dimensions see • Components for extending short pulses • Provides PLC versions with switch-on/off delay • Fixed times DKZA DK5 DKA DK5 Type Cat ...

Page 97

Timers Turn off delay module MCZ var v The timer module can be used for extending short pulses and fixed times. Provides PLC ver- sions with switch off delay. Schematic circuit diagram Ordering data For TS 35 ...

Page 98

155 ...

Related keywords