G3VM-351G Omron, G3VM-351G Datasheet
G3VM-351G
Specifications of G3VM-351G
Z2084
Available stocks
Related parts for G3VM-351G
G3VM-351G Summary of contents
Page 1
... Terminal Arrangement/Internal Connections (Top View) G3VM-351G ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-351G 82 Note: The actual product is marked differently from the image shown here. Model G3VM-351G 100 G3VM-351G(TR) --- 4.4± 0.25 3.9± 0.2 2.1 max. 0.15 0.4± 0.6± 0.1 0.3 0.1± ...
Page 2
... Safety Precautions Refer to “Common Precautions” for all G3VM models. G3VM-351G 1. The dielectric strength between the input and output was checked by applying voltage be- tween all pins as a group on the LED side and all pins as a group on the light-receiving side. ...
Page 3
... Terminal 3 is connected to the internal circuit. Do not connect anything to terminal 3 externally. Pin Strength for Automatic Mounting Load In order to maintain the characteristics of the relay, the force imposed on any pin of the relay for automatic mounting must not exceed the following. In direction A: 1. direction B: 1.96 N G3VM Series ...
Page 4
... Do not throw or drop components. If the laminated packag- ing material is damaged, airtightness will be lost. 6. Tape cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them. G3VM Series Soldering 230 to 260 ° max. 245 to 260 ° max. ...