AQY232SZ Panasonic Electric Works, AQY232SZ Datasheet

no-image

AQY232SZ

Manufacturer Part Number
AQY232SZ
Description
RELAY OPTO 60V 0.5A SOP4
Manufacturer
Panasonic Electric Works
Series
PhotoMOS™ AQYr
Datasheet

Specifications of AQY232SZ

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
2.5 Ohm
Load Current
500mA
Voltage - Input
1.14VDC
Voltage - Load
0 ~ 60 V
Mounting Type
Surface Mount
Termination Style
Gull Wing
Package / Case
4-SOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2690-2
TYPES
Note: For space reasons, the three initial letters of the part number “AQY”, the surface mount terminal indicator “S” and the packing style indicator “X” or “Z” are not marked
* Indicate the peak AC and DC values.
Ratings and packages other than those given above are available by special order. Please contact our sales office in your area.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Input
Output
Total power dissipation
I/O isolation voltage
Operating temperature
Storage temperature
dual use
N e w
Compliance with RoHS Directive
AC/DC
on the relay. (Ex. the label for product number AQY232SX is 232.)
voltage
1
2
350V
400V
Load
60V
Output rating*
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (peak AC)
Continuous load current
Peak load current
Power dissipation
.169
4.3
current
500mA
120mA
100mA
Load
4.4
.173
Item
2.1
.083
4
3
SOP4-pin
Package
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
mm
inch
Tube packing style
AQY232S
AQY230S
AQY234S
FEATURES
1. High sensitivity (Low current-
consumption)
HS type PhotoMOS relays need less than
half LED forward current of other types.
This contributes to energy-saving
working of equipment and longer
operating life for battery.
In case of load voltage 60V type, SOP4-pin
2. Small package (SOP4-pin)
3. 60 V, 350 V and 400 V load voltage
types available
LED
operate
current
Recommended LED
forward current
current 2 mA, High Sensitivity
Recommended LED forward
Symbol
(Low current-consumption),
Sensitivity comparison between
I
P
V
T
T
P
V
I
V
peak
P
I
Miniature SOP4-pin Type
FP
I
opr
out
stg
F
L
iso
R
in
L
T
HS type and GU type
Maximum
Typical
AQY232S
0.5 A
1.5 A
60 V
Picked from the
–40°C to +100°C
1/2-pin side
AQY232SX
AQY230SX
AQY234SX
–40°C to +85°C
Part No.
(AQY232S)
0.35 mA
HS type
0.5 mA
2 mA
Tape and reel packing style
1,500 V AC
AQY230S
300 mW
350 mW
75 mW
50 mA
0.12 A
350 V
0.3 A
5 V
1 A
(AQY212S)
–40°F to +185°F
–40°F to +212°F
GU type
0.9 mA
3 mA
5 mA
Picked from the
3/4-pin side
AQY232SZ
AQY230SZ
AQY234SZ
HS SOP 1 Form A (AQY2)
AQY234S
0.24 A
400 V
0.1 A
TYPICAL APPLICATIONS
Ideal for battery-powered devices that
need to lengthen operating life.
Also recommended for power-
economizing of testing equipment that
uses many relays.
1. Security equipment
• Crime-preventing system: Surveillance
camera, burglar alarm
• Disaster-preventing system: Fire alarm,
heat/smoke sensor
2. Measuring instruments
3. Meters (watt-hour, gas, etc.)
4. Telecommunication equipment
5. Industrial equipment
HS SOP 1 Form A
f = 100 Hz, Duty factor = 0.1%
Peak AC, DC
100ms (1 shot), V
Non-condensing at low temperatures
1 batch contains:
1 tube contains:
2,000 pcs.
100 pcs.
Tube
(AQY2)
Packing quantity
Remarks
L
= DC
Tape and reel
1,000 pcs.

Related parts for AQY232SZ

AQY232SZ Summary of contents

Page 1

... GU type 2. Measuring instruments (AQY212S) 3. Meters (watt-hour, gas, etc.) 0 Telecommunication equipment 5. Industrial equipment Packing quantity Tube Picked from the 3/4-pin side 1 tube contains: AQY232SZ 100 pcs. AQY230SZ 1 batch contains: AQY234SZ 2,000 pcs. AQY234S 100 Hz, Duty factor = 0.1% 350 V 400 V 0.1 A Peak AC, DC ...

Page 2

... LED current: 2 mA; Load voltage: Max. (DC); Continuous load current: Max. (DC AQY234S 30 AQY230S 20 10 AQY232S 0 –40 – Ambient temperature, °C All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. AQY230S AQY234S 0.35 mA 0.5 mA 0.1 mA 0.3 mA 1. mA Ω 27 Ω 25 Ω 35 Ω 1 µA 1 ...

Page 3

... Ambient temperature: 25°C 77°F 100 AQY232S AQY230S, AQY234S Applied voltage, V All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 5. LED operate current vs. ambient temperature characteristics Sample: All types; Load voltage: Max. (DC); Continuous load current: Max. (DC) 1.2 1 0.8 0.6 0.4 0.2 0 –40 – Ambient temperature, ° ...

Page 4

... For LED operate current at E maintain 2 mA. 2) Please make sure for higher max. the LED operate current at than 50 mA min. max. All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Recommended mounting pad (Top view) .047 2.54 .100 ±.006 Wiring diagram Load 4 4 ...

Page 5

... No the stopper B side. Observe correct orientation when mounting them on PC boards. Stopper B (green) Stopper A (gray) All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd recommend cleaning with an organic solvent. If you cannot avoid using ultrasonic cleaning, check beforehand for defects. 9. Input wiring pattern ...

Page 6

... R.H.). • If the devices are to be left in storage for a considerable period after the moisture- proof package has been unsealed recommended to keep them in another moisture-proof bag containing silica gel (within 3 months at the most). All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. ...