AQW614 Panasonic Electric Works, AQW614 Datasheet - Page 2

RELAY OPTO AC/DC 400V 100MA 8DIP

AQW614

Manufacturer Part Number
AQW614
Description
RELAY OPTO AC/DC 400V 100MA 8DIP
Manufacturer
Panasonic Electric Works
Series
PhotoMOS™ AQWr
Datasheets

Specifications of AQW614

Circuit
DPST-NO/NC (1 Form A and B)
Output Type
AC, DC
On-state Resistance
50 Ohm
Load Current
100mA
Voltage - Input
1.14VDC
Voltage - Load
0 ~ 400 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
8-DIP (0.300", 7.62mm)
Application
High-speed inspection machines, telephone equipment, computer
Capacitance, Output
0.8 pF (Typ.)
Contact Form
SPST-NO, SPST-NC
Current, Rating
100 mA
Function
General Purpose
Number Of Pins
8
Package Type
Tube
Relay Type
Solid State
Resistance, On-state
27 Ohms (Typ.), Output
Standards
cULus
Temperature, Operating, Minimum
-40 °C
Termination
Through Hole
Voltage, Rating
400 VAC/VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1980
AQW614

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AQW614
Manufacturer:
NAIS
Quantity:
2 100
Part Number:
AQW614
Manufacturer:
PANASONIC
Quantity:
20 000
Part Number:
AQW614-002
Manufacturer:
NAIS
Quantity:
5 510
Part Number:
AQW614-002
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
AQW614A
Manufacturer:
NAIS
Quantity:
5 510
Part Number:
AQW614AX
Manufacturer:
PANASONIC
Quantity:
12 000
Part Number:
AQW614AX
Manufacturer:
NAIS
Quantity:
1 000
Part Number:
AQW614AX
Manufacturer:
NAIS
Quantity:
3 739
Part Number:
AQW614AX
Manufacturer:
NAIS
Quantity:
20 000
Part Number:
AQW614EH
Manufacturer:
NAIS
Quantity:
3 671
Part Number:
AQW614EH
Manufacturer:
NAIS
Quantity:
20 000
GU Form A & B (AQW614)
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
*Operate/Reverse time
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper relay operation and resetting.
■ For Dimensions
■ For Schematic and Wiring Diagrams
■ For Cautions for Use
■ These products are not designed for automotive use.
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
Input
Output
Transfer
characteristics
Output
If you are considering to use these products for automotive applications, please contact your local Panasonic Electric
Works technical representative.
For more information
Input
Input LED current
140
120
100
80
60
40
20
0
–40
Using only 1 channel
Using 2 channels
Item
Ton
–20
0
Ambient temperature, °C
LED operate current
LED reverse current
LED dropout voltage
On resistance
Off state leakage current
Operate time*
Reverse time*
I/O capacitance
Initial I/O isolation resistance
20
1) N.O.
40
–40°F to +185°F
Item
60
Symbol
8085
I
F
100
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Toff
Typical
Maximum
Minimum
Typical
Typical
Maximum
Typical
Maximum
Maximum
Typical
Maximum
Typical
Maximum
Typical
Maximum
Minimum
90%
10%
2. On resistance vs. ambient temperature
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
Recommended value
Output
60
50
40
30
20
10
0
Input
5
–40
I
I
I
I
T
T
T
T
Fon
Foff
Foff
Fon
Symbol
on
off
off
on
–20
I
C
R
R
Toff
(N.O.)
(N.C.)
(N.O.)
(N.C.)
(N.O.)
(N.C.)
(N.O.)
(N.C.)
V
Leak
iso
iso
on
F
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
Ambient temperature, °C
0
20
2) N.C.
40
Unit
mA
60
0.28 ms (N.O.) 0.43 ms (N.C.)
0.04 ms (N.O.) 0.3 ms (N.C.)
8085
1.25 V (1.14 V at I
AQW614(A)
1,000 MΩ
Ton
0.9 mA
0.4 mA
0.8 mA
0.8 pF
1.5 pF
3 mA
1.5 V
27 Ω
50 Ω
1 µA
1 ms
1 ms
3. Operate time vs. ambient temperature
characteristics
LED current: 5 mA;
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
10%
90%
F
= 5 mA)
1.2
1.0
0.8
0.6
0.4
0.2
0
–40
–20
Ambient temperature, °C
Between terminal 5 and 6 (N.O.)
Between terminal 7 and 8 (N.C.)
0
20
I
I
I
I
I
I
within 1 s on time
I
I
V
I
I
I
I
f = 1 MHz
V
500 V DC
L
L
F
F
F
L
F
F
F
L
F
L
L
B
= 100 mA
= 100 mA
= 50 mA
= 5 mA (N.O.)
= 0 mA (N.C.)
= 100 mA
= 0 mA (N.O.)
= 5 mA (N.C.)
= 0 mA ➝ 5 mA
= 100 mA
= 5 mA ➝ 0 mA
= 100 mA
40
= 400 V
= 0 V
Condition
60
8085

Related parts for AQW614