HD4850-10 Crydom Co., HD4850-10 Datasheet

RELAY SSR 50A 480VAC DC

HD4850-10

Manufacturer Part Number
HD4850-10
Description
RELAY SSR 50A 480VAC DC
Manufacturer
Crydom Co.
Series
HDr
Datasheets

Specifications of HD4850-10

Load Current
50A
Circuit
SPST-NO (1 Form A)
Output Type
AC
Voltage - Input
3 ~ 32VDC
Voltage - Load
48 ~ 530 V
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Package / Case
Hockey Puck
Control Voltage Range
3VDC To 32VDC
Operating Voltage Range
48Vrms To 530Vrms
Isolation Voltage
4000Vrms
Control Voltage Type
DC
Relay Terminals
Screw Clamp
Input Type
DC
Input Voltage (max)
32V
Output Voltage (max)
530V
Input Current (max)
2mA
Output Current
50A
Output Device
SCR
Pin Count
4
Mounting
Screw
Operating Temp Range
-40C to 80C
Operating Temperature Classification
Commercial
Rad Hardened
No
Load Voltage Rating
530 V
Load Current Rating
50 A
Mounting Style
Panel
Relay Type
Solid State
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Compliant
Other names
CC1096
HA / HD48 Series
PRODUCT SELECTION
Control Voltage
3-32 VDC
90-280 Vrms
18-36 Vrms
90-280 Vrms
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current (3) [Arms]
Minimum Load Current [mArms]
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A2 sec]
Minimum Power Factor (with Maximum Load)
HA4812E
HD4812
HA4812
HA4812
12A
• Ratings from 12A to 125A @ 48-530 VAC
• SCR output for heavy industrial loads
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
HA4825E
HD4825
HA4825
HA4825
25A
134/140
48-530
12A
89/81
1200
1.48
500
1.7
0.5
10
12
40
HA4850E
HD4850
HA4850
HA4850
50A
239/250
285/259
48-530
25A
1200
1.02
500
1.7
0.5
10
25
40
HA4875E
HD4875
HA4875
HA4875
75A
1779/1621
597/625
48-530
50A
1200
0.63
500
1.7
0.5
10
50
40
4555/4150
954/1000
48-530
HA4890E
75A
1200
HD4890
HA4890
HA4890
0.31
500
1.7
0.5
10
75
40
90A
1145/1200
6560/5976
48-530
90A
1200
0.28
500
1.7
0.5
10
90
40
HA48110E
HD48110
HA48110
HA48110
110A
10249/9338 13950/12709
1432/1500
110A
48-530
1200
0.25
500
110
150
1.7
0.5
10
HA48125E
HD48125
HA48125
HA48125
125A
1670/1750
125A
48-530
1200
0.22
500
125
150
1.7
0.5
10

Related parts for HD4850-10

HD4850-10 Summary of contents

Page 1

... Minimum Power Factor (with Maximum Load) • Ratings from 12A to 125A @ 48-530 VAC • SCR output for heavy industrial loads • control • Zero-crossing (resistive loads) or random-fire (inductive loads) output 25A 50A HD4825 HD4850 HD4875 HA4825 HA4850 HA4875 HA4825E HA4850E HA4875E ...

Page 2

... Heat sinking required, for derating curves see page VAC Input option, E suffix 5) Turn-on time for random turn-on versions is 0.02 msec (DC control Models) 6) Input circuitry incorporates active current limiter. 7) For relays with option ”G” minimum control voltage is 4.5VDC MECHANICAL SPECIFICATIONS D PREFIX A PREFIX 3-32 VDC (7) 90-280 Vrms 3 ...

Page 3

THERMAL DERATE INFORMATION AGENCY APPROVALS E116949 LR81689 10143 UG Rev. 012711 ...

Page 4

...

Page 5

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords