H3CR-F8 DC12 Omron, H3CR-F8 DC12 Datasheet - Page 16

RELAY REPEAT CYCLE ANALOG 30HRS

H3CR-F8 DC12

Manufacturer Part Number
H3CR-F8 DC12
Description
RELAY REPEAT CYCLE ANALOG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Type
Solid State Twin Timerr
Datasheet

Specifications of H3CR-F8 DC12

Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Analog / Digital
Analog
Control Method
Dial
Voltage Rating
12 VDC
Mounting
DIN Rail
Display Type
Dial
Size
52.3 mm x 48 mm x 48 mm
Features
Easy sequence checks through instantaneous outputs for a zero set value at any time range
Input Type
Voltage
Rohs Compliant
YES
Contact Configuration
DPDT
Timing Adjustment
Knob
Relay Mounting
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F8-DC12
H3CR-F8-DC12
H3CRF8DC12
Q3594182
Z2815
■ Life-test Curve
Connections
■ Block Diagrams
■ I/O Functions
Without Reset Input (H3CR-H8L)
With Reset Input (H3CR-H8RL/-HRL)
Inputs
Outputs
10,000
1,000
5,000
100
500
250 VAC (cosφ = 0.4)
AC (DC) input
AC (DC) input
Reset
Control output
Load current (A)
http://www.ia.omron.com/
30 VDC L/R = 7 ms
Reset input
250 VAC/30 VDC
(cosφ = 1)
Power failure
detection circuit
Power failure
detection circuit
Power supply
circuit
Power supply
circuit
Turns off the control output and resets the elapsed time.
Operates instantaneously when the power is turned on and time-limit resets when the set time is up
after the power is turned off.
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)
Oscillation
circuit
Oscillation
circuit
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC for H3CR-H8L/-HRL
and 100 mA at 5 VDC for H3CR-H8RL (failure level: P).
Input circuit
Time range/
unit selector
Time range/
unit selector
Counting
circuit
Counting
circuit
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Indicator
circuit
Indicator
circuit
Output
circuit
Output
circuit
Output
indicator
Output
indicator
H3CR-H
16