88826155 Crouzet USA, 88826155 Datasheet - Page 3

RELAY TIME ANALG 10A 24-240V DIN

88826155

Manufacturer Part Number
88826155
Description
RELAY TIME ANALG 10A 24-240V DIN
Manufacturer
Crouzet USA
Series
MLR1r
Datasheets

Specifications of 88826155

Relay Type
Integrated
Function
Repeat Cycle
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 100 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
10A @ 250VAC
Voltage - Supply
24 ~ 240VAC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Contact Form
SPDT
Current, Rating
10 A
Power, Rating
2000⁄80 VA⁄W
Repeatability
± 0.5%
Reset Time
350 ms
Standards
UL, cUL, CSA, CE
Temperature, Operating
-20 to +60 °C
Termination
Screw
Timer Type
Repeat Cycle
Timing Range
0.1 to 1 sec., 1 to 10 sec., 10 sec. to 1 min., 1 to 10 min., 10 min. to 1 hr., 1 to 10 hrs., 10 to 100 hrs.
Voltage, Control
240⁄24 VAC⁄VDC
Voltage, Rating
250 V
Supply Voltage
24 V to 240 V
Contact Rating
10 A at 250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
646-1178
88826155-MLR1
4-20
Chronos 2 electronic timers - 17.5 mm
Solid state output
For special features, functions etc. please contact us.
Technical specifications
Timing
Repetition accuracy (with constant
parameters)
Drift
- Temperature
- Voltage
Display precision according to IEC 1812-1
Minimum pulse duration
- Typically (relay version)
- Typically (solid state version)
- Typically under load (relay version)
Maximum reset time by de-energisation
- Typically (relay version)
- Typically (solid state version)
Immunity to breaks in supply voltage: typically
Power supply
Multi-voltage power supply
Frequency
Operating range
Load factor
Maximum power consumption
Output elements: Solid state output
Rated power
Derating
Maximum admissible current
Minimum breaking current
Off-state leakage
Voltage breaking capacity
Maximum voltage drop at terminals
Electrical life
Mechanical life
Breakdown voltage acc. to IEC 664, IEC 255-5
Display
State displayed by 1 LED
- Flashing green when on
Green LED operation indicator
- timer on, no timing in progress
- timing in progress
- Relay waiting, no timing in progress
Input type
- Volt-free contact
- 3-wire PNP output control option maximum
residual voltage: 0.4 V whatever the timer
power supply
(except functions Di-D and Li-L)
Multi-function or mono-function
Multi-range (7 ranges, available options)
Multi-voltage
Solid state output: 0.7 A - 250 V (0.5 A UL)
Screw or spring terminals
1 LED status indicator
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
Pulsing:
Flashing:
Permanently lit:
Other information
Products and specifications subject to change without notice.
Consult factory for application assistance.
± 0.5 %
(CEI 1812-1)
± 0.05 % / °C
± 0.2 % / V
±10 % / 25 °C
30 ms
50 ms
100 ms
100 ms
350 ms
>10 ms
depending on version,
see page 6/5
50/60 Hz
85 to 110 % Un
(85 to 120 % Un for
12V AC/DC)
100 %
0.6 W 24V AC/DC
1.5 W 230V AC
32 VA 230V AC
0.7 A AC/DC
20 °C (0,5A UL)
5 mA / °C
20 A ≤ 10 ms
10 mA
< 5 mA
250V AC/VDC
3 fils 4V - 2 fils 8V
10
10
2.5 kV to 1 mA / 1 min.
0.4 V
8
8
operations
operations
Timing
Types
Part numbers and voltage
24 • 240 V a 50 • 60 Hz
24 • 240 V a c 50 • 60 Hz
Functions
Nominal current
Timing ranges
1s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h
General specifications
Conforming to standards
IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV
directives (73/23/EEC + 93/68/EEC
(CE marking) + EMC (89/336/EEC +
IEC 669-2-3 (17.5 mm)
Approvals
UL cUL listed
Temperatures limits
- use
- stored
Installation category (acc. to IEC 664-1)
Creepage distance and clearance acc. to
IEC 664-1
Degree of protection acc. to IEC 529
- terminal block
- casing
- front face (except Tk2R1)
Vibration resistance acc. to IEC 68-2-6
Relative humidity acc. to IEC 68-2-3
without condensation
Electromagnetic compatibility
- Immunity to electrostatic discharges acc. to
IEC 1000-42
- Immunity to electrostatic fields acc. to
ENV 50140/204 (IEC 1000-4-3)
- Immunity to rapid transient bursts acc. to IEC
1000-4-4
- Immunity to shock waves on power supply
acc. to IEC 1000-4-5
- Immunity to radiofrequency in common mode
acc. to ENV
- Immunity to voltage dips and breaks acc. to
IEC 1000-4-11
- Mains-borne and radiated emissions acc. to
EN 55022 (EN 55011 Group 1)
Fixing: Symmetrical DIN rail (EN 50022)
Connection capacity
- without ferrule
- with ferrule
Spring terminals, 2 terminals per connection point
- flexible wire
- rigid wire
Casing material
Weight: 17.5 mm casing
CSA recognized
(7 ranges)
-20 °C + 60 °C
-30 °C + 60 °C
Voltage surge
category
4 kV / 3
IP 20
IP 40
IP 50
f = 10 • 55 Hz
A = 0.35 mm
93 %
Level III
(Air 8 K /
Contact 6 KV)
Level III 10V/m:
80 MHz to 1 GHz)
Level III (direct 2kV/
Capacitive coupling
clamp 1 KV)
Level III (common
mode 2 KV / residual
current mode 1KV)
Level III (10V rms:
0.15 MHz to 80 MHz)
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
35 mm
2 x 2.5 mm
2 x 1.5 mm
1.5 mm
2.5 mm
Self-extinguishing
60 g
2
2
2
2

Related parts for 88826155