88865265 Crouzet USA, 88865265 Datasheet - Page 3

RELAY TIME ANALOG 8A 24-240V DIN

88865265

Manufacturer Part Number
88865265
Description
RELAY TIME ANALOG 8A 24-240V DIN
Manufacturer
Crouzet USA
Series
TK2R1r
Datasheets

Specifications of 88865265

Time Range
1sec To 100hr
Power Consumption
1.5W
Reset Time
100ms
Supply Voltage Ac, Max
240V
Mounting Type
DIN Rail
Time Range Min
0.06s
Signal Input Type
Volt-Free Contact
Relay Type
Integrated
Function
Off-Delay
Circuit
DPDT (2 Form C)
Delay Time
0.1 Sec ~ 100 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
8A @ 250VAC
Voltage - Supply
24 ~ 240VAC
Termination Style
Screw Terminal
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Contact Form
DPDT
Current, Rating
10 A
Power, Rating
2000⁄80 VA⁄W
Standards
UL, CSA, CE
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-20 °C
Termination
Screw
Timer Type
Off Delay
Timing Range
0.1 to 1 sec., 1 to 10 sec., 6 to 60 sec., 1 to 10 min., 6 to 60 min., 1 to 10 hrs., 10 to 100 hrs.
Voltage, Control
240⁄24 VAC⁄VDC
Voltage, Rating
250 V
Supply Voltage
24 V to 240 V
Contact Rating
8 A at 250 VAC
Supply Current
10A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
646-1183
4
2/36
Chronos 2 electronic timers - 22.5 mm
Non stocked items, minimum order quantity 100 units.
Relay output 2 DPDT relays
Technical specifications
Timing
Repetition accuracy (with constant
parameters)
Drift
- Temperature
- Voltage
Display precision according to IEC 1812-1
Minimum pulse duration
- Typically (relay version)
- Typically (solid state version)
- Typically under load (relay version)
Maximum reset time by de-energisation
- Typically (relay version)
- Typically (solid state version)
Immunity to breaks in supply voltag: typically
Power supply
Multi-voltage power supply
Frequency
Operating range
Load factor
Maximum power consumption
Output elements relay output
1 or 2 changeover relays, AgNi (cadmium-free)
Rated power
Maximum breaking current
Minimum breaking current
Voltage breaking capacity
Electrical life
Mechanical life
Breakdown voltage acc. to IEC 1812-1
Impulse voltage acc. to IEC 664-1 IEC 1812-1
Display
State displayed by 2 LEDs
- Flashing green when on
- Relay LED yellow during timing
Green LED operation indicator
- timer on, no timing in progress
- timing in progress
- Relay waiting, no timing in progress
Input type
- Volt-free contact
- 3-wire PNP output control option maximum
residual voltage: 0.4 V whatever the timer power
supply
(except functions Di-D and Li-L)
Multi-function or mono-function
Multi-range (7 ranges, available options)
Multi-voltage
Relays output 2: 8 A - 250 V (10 A UL) including
1 instantaneous
Screw terminals
1 LED status indicators
Option of connecting an external power supply to the
control input
3-wire sensor control option
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
Pulsing:
Flashing:
Permanently lit:
Other information
Products and specifications subject to change without notice.
Consult factory for application assistance.
± 0.5 %
(CEI 1812-1)
± 0.05 % / °C
± 0.2 % / V
±10 % / 25 °C
30 ms
50 ms
100 ms
100 ms
350 ms
>10 ms
depending on version,
see page 1/13
50/60 Hz
85 to 110 % Un
(85 to 120 % Un for
12V AC/DC)
100 %
0.6 W 24V AC/DC
1.5 W 230V AC
32 VA 230V AC
2000 VA / 80 W
2000 V A / 80W
10 A AC 10 A DC
10 mA / 5 VDC
250V AC/VDC
10
8 A 250V resistive
5 x 10
2.5 kV / 1min /
1 mA /50Hz
5 kV, wave 1.2 / 50 s
0.4 V
5
operations
6
operations
Timing
Types
Part numbers and voltage
24V c / 24 • 240V a
12 V a / c
Functions
Nominal current
Timing ranges
0.1s - 1s - 10 s , 6s - 60s , 1 min - 10 min , 6min - 60min , 1 h - 10 h - 100 h
TK2R1 (4 ranges)
0.06 s - 0.6 s - 2.5 s - 20 s - 160 s
General specifications
Conforming to standards
IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV
directives (73/23/EEC + 93/68/EEC
(CE marking) + EMC (89/336/EEC +
IEC 669-2-3 (17.5 mm)
Approvals
UL - CSA - cUL pending
Temperatures limits
- use
- stored
Installation category (acc. to IEC 664-1)
Creepage distance and clearance acc. to
IEC 664-1
Degree of protection acc. to IEC 529
- terminal block
- casing
- front face (except Tk2R1)
Vibration resistance acc. to IEC 68-2-6
Relative humidity acc. to IEC 68-2-3
without condensation
Electromagnetic compatibility
- Immunity to electrostatic discharges acc. to
IEC 1000-42
- Immunity to electrostatic fields acc. to
ENV 50140/204 (IEC 1000-4-3)
- Immunity to rapid transient bursts acc. to IEC
1000-4-4
- Immunity to shock waves on power supply acc.
to IEC 1000-4-5
- Immunity to radiofrequency in common mode
acc. to ENV
- Immunity to voltage dips and breaks acc. to
IEC 1000-4-11
- Mains-borne and radiated emissions acc. to
EN 55022 (EN 55011 Group 1)
Fixing: Symmetrical DIN rail (EN 50022)
Connection capacity
- without ferrule
- with ferrule
Casing material
Weight: 22.5 mm casing
(7 ranges)
-20 °C + 60 °C
-30 °C + 60 °C
Voltage surge
category
4 kV / 3
IP 20
IP 40
IP 50
f = 10 • 55 Hz
A = 0.35 mm
93 %
Level III
(Air 8 K /
Contact 6 KV)
Level III 10V/m:
80 MHz to 1 GHz)
Level III (direct 2kV/
Capacitive coupling
clamp 1 KV)
Level III (common
mode 2 KV / residual
current mode 1KV)
Level III (10V rms:
0.15 MHz to 80 MHz)
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
35 mm
2 x 2.5 mm
2 x 1.5 mm
Self-extinguishing
90 g
2
2

Related parts for 88865265