343C2 TPI (Test Products Int), 343C2 Datasheet

THERM DIG W/DUAL K-TYPE PROBE

343C2

Manufacturer Part Number
343C2
Description
THERM DIG W/DUAL K-TYPE PROBE
Manufacturer
TPI (Test Products Int)
Type
Handheldr
Datasheets

Specifications of 343C2

Temperature Range
-58 ~ 2462°F (-50 ~ 1350°C)
Temperature Display
C°/F°
Display Type
LCD
Input Type
Thermocouples (2)
Features
Auto Off, MIN/MAX, T1/T2/DeltaT, Water Resistant
Probe Type
K
Battery Type
9 Volt
Includes
Boot, Pouch, Thermocouple - K-Type Bead Probe (2)
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Other names
290-1416
TPI offers a
complete
line of…
CO, Combustibles &
Combustion (CEA)
Refrigerant Leak
Detectors
Digital Manometers
Temperature
Contact & IR
Instruments
IAQ: Air Flow &
Humidity
Handheld
Oscilloscopes
Digital Multimeters
& Clamp-on Meters
Accessories & Kits
Test Products
International, Inc.
Headquarters:
9615 SW Allen Blvd.
Beaverton, OR 97005
USA
503-520-9197
Fax: 503-520-1225
e-mail:
info@tpi-thevalueleader.com
Test Products
International, Ltd.
342 Bronte St. South
Unit #9
Milton, Ontario L9T
5B7
Canada
905-693-8558
Fax: 905-693-0888
e-mail:
info@tpicanada.com
Test Products
International UK Ltd.
Longley House,
East Park
Crawley, West Sussex
RH10 6AP England
Tel:
+44 (0)1293 561212
Fax:
+44 (0)1293813465
contactus@tpieurope.com
L TAW DCT-0805
PROBES USING THE HK11M HANDLE
CK18M
CK21M
FK26M
GK11M
GK12M
GK13M
GK14M
CK15M
GK16M
HK11M
FK13M
CK18M
K-type
thermocouple
surface probe
CK21M
K-type
thermocouple
pipe clamp for pipe
diameters up 1.2”
and temp. up to 212°F
FK26M
For use with
Pete’s plugs to
measure water
temperature
GK11M
Standard
K-type
thermocouple
probe
GK12M
Standard
K-type
thermocouple
probe w/ oven
clip
GK13M
Beaded probe
with FDA
approved
insulation
GK14M
K-type
air probe
shielded to
protect sensing
area
CK15M
Heavy duty
K-type surface
probe to use with
HK11M handle
FK13M
K-type general
purpose probe
to use with
HK11M handle
GK16M
K-type
air probe
for use with
HK11M handle
HK11M
Heavy-duty
handle for
K-type
thermocouple
probes
Model #
Description
Copyright © 2005 Test Products International, Inc.
Restaurant
grills
Pipe Clamp
For Pete’s
Plug
Air Temp.
Food
Processing
General
purpose.
Air.
Food
Immersion
Temp.
Surface
Food
Processing
Air Temp
Use with
Above
Attachments
Application
Temperature Probes
-58° to 482°F
-50° to 250°C
-58° to 212°F
-50° to 100°C
-40° to 400°F
-40° to 204°C
-40° to 9500°F
-40° to 510°C
-40° to 950°F
-40° to 510°C
-40° to 400°F
-40° to 204°C
-40° to 510°F
-40° to 265°C
-40° to 510°F
-40° to 950°C
-40° to 850°F
-40° to 454°C
-40° to 500°F
-40° to 260°C
NA
NA
Range°F°C
Stem Length: 2.4”
Diameter: 6.0mm
Lead Length: 1M
Stem Length:NA
Diameter: NA
Lead Length: 1M
Stem Length:
Diameter:
Lead Length:
Stem Length: NA
Diameter: NA
Lead Length: 1.2M
Stem Length: NA
Diameter: NA
Lead Length: 1.2M
Stem Length: NA
Diameter: NA
Lead Length: 1.2M
Stem Length: 4”
Diameter: 3.75mm
Lead Length: 1M
Stem Length: 4”
Diameter: 3.75mm
Lead Length: NA
Stem Length: 8”
Diameter: 3.75mm
Lead Length: 1M
Stem Length: 8”
Diameter: 3.75mm
Lead Length: NA
Stem Length: NA
Diameter: NA
Lead Length: 3’
Dimensions
Polyurethane
PVC
Teflon
Fiberglass
Fiberglass
Teflon
PVC
NA
PVC
NA
NA
Insulation
Material
What is the difference between thermocouple and
thermistor probes?
Thermocouple probes utilize the reaction between
two dissimilar metals to produce a voltage that
changes as temperature changes. A thermistor is a
resistive device that produces a change in
resistance with a change in temperature. In general,
thermocouples offer a wider temperature range and
quicker response time than thermistors.
Thermistors are typically more accurate than
thermocouples.
What are the differences between thermocouple
types?
Each thermocouple uses different metals and
therefore have different characteristics. Here are
general guidelines:
K-Type - Wide temperature range, used in many
digital thermometers and multimeters. Identified by
a yellow connector.
J-Type -Narrower temperature range than K-type,
used in analog and digital thermometers. Identified
by a black connector.
T-Type -Narrower temperature range than J-type
but more accurate than K and J types, used in
digital thermometers. Identified by a blue connector.
Can different thermocouple types be
interchanged?
No. Since each thermocouple type uses different
metals in it's construction they have different output
characteristics. Using a J-type thermocouple in a K-
type thermometer will cause measurements to be
very inaccurate.
What type of probe should I use?
The type of probe you purchase depends on your
specific application. Here are general guidelines for
different probe types.
Penetration (F) -General-purpose probe used for
immersion and air temperature measurements.
Response time in air will be slower than an air
probe because the tip is not exposed.
Chisel (F) -General-purpose tip used for surface,
immersion, and air temperature measurements.
Response time in air or on surfaces will be slower
than an air or surface probe because of the tip
design.
Air (G) -Exposed tip probe provides the fastest
response time when measuring air temperatures.
Not useful for surface or immersion testing.
Surface (C) -Contact tip probe provides the fastest
response time when measuring surface tempera-
tures. Probe tip designed to offer maximum
temperature transfer in surface applications. Not
useful for air or immersion testing.
Beaded (G) -General-purpose probe used in
immersion and air temperature measurements.
Exposed tip allows for fast reaction time. Not useful
in semi-solids.
What are the differences between the connector
types TPI offers?
Sub-Mini -This is an industry standard connector
type allowing TPI probes to be used in any thermo-
couple thermometer using this type of connector.
Lumberg -This connector uses a screw collar to
attach to the thermometer and is the most secure
connection available.
Bi-Polar -This connector is used in the TPI
thermistor probe line.
FA Q
PROBE
The
Value
Leader
Grill & surface
temperatures,
temperatures,
Cables, circuit
temperatures
transformers
thermostats,
connections,
Ambient Air,
Compressor
Temperature
differential,
Electrical:
machinery,
Registers,
breakers,
cabinets,
Calibrate
HVAC/R:
motors,
holding
serving
storage
heads,
Food:
Vents
Sold as Kits, complete and ready to use!
340C1: 340 temperature tester, A304 tilt stand boot, GK12M probe, 9V battery and
A340 soft pouch
341C1: 341 temperature tester, A304 tilt stand boot, GK11M (950°F) fiberglass
probe, 9V battery, and A340 soft pouch
342C1: 342 temperature tester, A304 tilt stand boot, two GK11M (950°F)
fiberglass probes, 9V battery, A340 soft pouch
342C2: 342 temperature tester, A304 tilt stand boot, two GK13M (500°F) Teflon
probes, 9V battery, A340 soft pouch
343C1 (For High Temperature, over 400°F): 343; A304 tilt-stand protective boot; (2)
GK12M fiberglass, beaded, K-type thermocouple probes; A340 soft pouch
343C2 (For Low Temperature, under 400°F): 343; A304 tilt-stand protective boot; (2)
GK13M Teflon, beaded, K-type thermocouple probes; A340 soft pouch
343C3 (For Differential Temperature): 343; A304 tilt-stand protective boot; (2) CK21M
K-type thermocouple pipe clamp probes; (1) GK13M Teflon, beaded, K-type
thermocouple probe; A908 shoulder strap carrying case
351F1: 351 temperature tester, A304 tilt stand boot, FX12B probe, 9V battery,
A340 soft pouch
Water Resistant
Min/Max Record
Selectable Res.
° C/° F Selectable
T1, T2, T Select
Scan Mode
Auto Off
Field Cal. Mode
Range K-type
Range J-type
Range T-type
Basic Accuracy*
Size
Weight
Battery
Protective Boot
Hard Carrying Case
FEATURES
Centigrade Version: Model 340C1X
These reliable, water-resistant testers accept K-type and J-type thermocouple probes.
HVAC/R professionals benefit from the 2-channel version that takes simultaneous
readings with T1/T2 selection.
Digital Contact Thermometers
340
Yes
NA
NA
NA
NA
NA
NA
NA
-58° to 1832° F
NA
NA
±0.5% + 5 digits
41mm x 152mm
x 77mm
278g w/boot
AAA
A304 included
No
340
341
Yes
Yes
Yes
Yes
NA
NA
Yes (after 20 min.)
NA
-328° to 2,462° F
-200° to 1,350° C
-328° to 1,832° F
-200° to 1,000° C
NA
±0.3%
41mm x 152mm
x 77mm
278g w/boot
9V
A304 included
No
341
342
Yes
Yes
Automatic
Yes
Yes (dual inputs)
NA
Yes (after 20 min.)
NA
-328° to 2,462° F
-200° to 1,350° C
-328° to 1,832° F
-200° to 1,000° C
NA
±0.3%
41mm x 152mm
x 77mm
278g w/boot
9V
A304 included
No
*Accuracy will depend on selection of probe.
342
343
Yes
Yes
Automatic
Yes
Yes (dual inputs)
NA
Yes (after 20 min.)
Yes
-58° to 2,462° F
-50° to 1,350° F
NA
NA
±0.3%
41mm x 152mm
x 77mm
278g w/boot
9V
A304 included
No
TPI 351: Perfect for the food industry
343
362
Yes
Yes
Automatic
Yes
Yes (dual inputs)
Yes
Yes (after 30 min.)
NA
-418° to 2,500° F
-200° to 1,375° C
-328° to 1,832° F
-200° to 1,000° C
-418° to 752° F
-250° to 400° C
±0.1%
41mm x 170mm
x 75mm
260g
9V
Yes
FEATURES
• Accuracy with Thermistor is ±1°
• Verify Calibration Optional test caps
• Water Resistant Take measurements
• Automatic Power Off Shuts down after
• Open Probe Indicator Displays “open”
351 SPECIFICATIONS
Thermistor Probe Range -40° to 220° F
Centigrade Version Model 351X available
(32° to 158° F)
available
in any environment
three minutes of inactivity
when probe is open or unattached
362
thermocouple, low-battery
indicator, and easy on-site
thermometer calibration
checking. Accuracy at 23° C
is ±0.5 or 0.9%° F
VKC300M
Centigrade version.
TILT BOOT
Standard Protective
Boot A304
Enjoy upright viewing.
Built-in tilt stand also frees
the hand. Store your
instru-ment face down inside
boot to protect the screen.
Calibrator
VKF300M
Reliable K-type
(340, 341, 342)

343C2 Summary of contents

Page 1

... High Temperature, over 400°F): 343; A304 tilt-stand protective boot; (2) GK12M fiberglass, beaded, K-type thermocouple probes; A340 soft pouch 343C2 (For Low Temperature, under 400°F): 343; A304 tilt-stand protective boot; (2) GK13M Teflon, beaded, K-type thermocouple probes; A340 soft pouch 343C3 (For Differential Temperature): 343 ...

Page 2

... Part numbers are 363X and 365X Models 364 and 366 offer ° ° F selection. The 363, 364, 365, and 366 digital thermometers come with A604 protective boot and no probes. The 363, 364, 365, and 366 boots do not have tilt stands. ...