VPP24-210 Triad Magnetics, VPP24-210 Datasheet

TRANSF 12VAC .42A WORLD SERIES

VPP24-210

Manufacturer Part Number
VPP24-210
Description
TRANSF 12VAC .42A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP24-210

Maximum Power
5 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
24 VAC @ 210mA
Parallel Output Voltage @ Current
12 VAC @ 420mA
Mounting Type
Through Hole
Dimensions
1.31 in L x 1.63 in W x 1.38 in H
Product
World Series Transformers
Height
1.38 in
Length
1.31 in
Width
1.63 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
24V
Current Rating
420mA
Power Rating
5VA
Transformer Mounting
PC Board
Secondary Current Nom
0.42A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 12V
Leaded Process Compatible
Yes
Output Current
0.42A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10498
237-1085
VPP24–210
Electrical Specifications (@25C)
1. Maximum Power: 5.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.025 SQ
C. WT Lbs. : 0.37
D. Mounting Holes: 0.112 dia. x 2.0
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
1.062
Inherently limited. No fusing required. Class 3.
Inherently limited. No fusing required. Class 2 not wet, Class 3 wet.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
L flammability requirements.
orld Series Transformers are designed and manufactured to meet the following agency approvals:
A
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
1.375
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
B
3
:
1
: 24.0V CT@ 0.21A; Parallel
0.187
C
0.200
D
0.400
E
22520B Temescal Canyon Road
Corona, California
92883
1.312
F
2
: 12.0V @ 0.42A
Units: In inches
1.625
G
1.000
H
P
P C M
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
4
6
3
1
SCHEMATIC
1
3
4
6
c
S
B
F
R
E R I E S
A
US
H
10
12
R
7
9
C
G
E
12
10
D
D
9
7

Related parts for VPP24-210