IT253 Schaffner EMC Inc, IT253 Datasheet

XFRMR PULSE 1:1:1 DL 1.1MH .25A

IT253

Manufacturer Part Number
IT253
Description
XFRMR PULSE 1:1:1 DL 1.1MH .25A
Manufacturer
Schaffner EMC Inc
Series
ITr
Datasheet

Specifications of IT253

Transformer Type
Data/Voice Coupling
Inductance
1.1mH
Turns Ratio - Primary:secondary
1 : 1 : 1
Mounting Type
Through Hole
Primary Voltage Rating
500 V
Secondary Voltage Rating
3.2 KV
Mounting Style
Through Hole
Dimensions
17.6 mm L x 16.7 mm W x 11.3 mm H
Product
Pulse Transformers
Height
11.3 mm
Length
17.6 mm
Width
16.7 mm
Dc Resistance
550mohm
Et Constant
160V/µs
Turns Ratio
1
Transformer Mounting
PC Board
Supply Voltage
500V
Leaded Process Compatible
Yes
Rohs Compliant
Yes
Winding Configuration
1
Winding Resistance Max
0.55ohm
Isolation Voltage
3.2kV
Capacitance
6pF
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E.t.
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
22-448
817-1517
IT 253
Technical specifications
Nominal operating voltage:
Operating frequency:
Ignition currents:
Rise time:
Test voltage:
Max. partial discharge voltage:
Temperature range (operation and storage):
Flammability corresponding to:
IT pulse transformers are designed to offer
you galvanic isolation for transformer coupled
gate drives. The IT series provides negligible
delays and the possibility of voltage scaling.
They are available with single or double
secondary winding for multiple gate drives.
Choosing the IT product line brings you the
rapid availability of a standard gate drive
transformer. A wide selection on turns ratio,
ignition current and voltages are designed to
offer you the desired standard product.
Pulse transformer with double
secondary winding
Up to 500V
40kHz max.
500kHz max. for data transmission
0.1 to 1A @ 40°C
0.4 to 4.0μs
U
1.5 x U
-25°C to +70°C (25/70/21)
UL 94V-0 listed materials
Features and benefits
p
/50Hz/2s max. according to VDE 110b
Galvanic separation of drive and power
circuit
Voltage resistance up to 4kV
Ignition current up to 1A
Turns ratio up to 3:1:1
Galvanic separation with secondary
winding.
Voltage resistance up to 4kV.
Allows high potential difference voltage
scaling.
Vacuum potting.
Very low partial discharge effects.
PCB through hole mounting.
Custom-specific versions on request.
nom
Pulse transformers
IT series
Approvals
Typical electrical schematic
Typical applications
Gate drive circuit
Power supplies
Power converters
Frequency converters
Switching applications
DC/DC converters
Line coupling transformers in high-speed
data transmission
sec.
prim.
sec.

Related parts for IT253

IT253 Summary of contents

Page 1

... Test voltage: Max. partial discharge voltage: Temperature range (operation and storage): Flammability corresponding to: IT pulse transformers are designed to offer you galvanic isolation for transformer coupled gate drives. The IT series provides negligible delays and the possibility of voltage scaling. They are available with single or double secondary winding for multiple gate drives ...

Page 2

... Explanations: – rise time at given load resistor R and 70% of the output pulse height. – primary inductance measured at 1kHz (secondary coile open). – L str stray inductance measured at the secondary side, short circuit at the primary side. If there are several secondary coils only one at the time is connected (measuring frequency 10kHz). ...

Page 3

Components > IT series Dimensions IT 213 IT 243 IT 244 A Ø19 17.6 17.6 B 16.7 16 11.3 11 0.45 0.42 0. 0.4 0 15.3 15.3 H ...