PESD0402-060 Tyco Electronics, PESD0402-060 Datasheet

ESD PROTECTOR 0402 6VDC POLYMER

PESD0402-060

Manufacturer Part Number
PESD0402-060
Description
ESD PROTECTOR 0402 6VDC POLYMER
Manufacturer
Tyco Electronics
Datasheet

Specifications of PESD0402-060

Voltage - Reverse Standoff (typ)
6V
Polarization
Bidirectional
Mounting Type
Surface Mount
Package / Case
0402 (1005 Metric)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Voltage - Breakdown
-
Other names
PESD0402-060
PESD0402-060TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PESD0402-060(D28058-000)
Manufacturer:
TYCORAYCHEM
Quantity:
11 000
308 Constitution Drive
Menlo Park, CA 94025-1164
Phone: 800-227-4856
www.circuitprotection.com
APPLICATIONS
MATERIALS INFORMATION
PART NUMBERING
The operating voltage is used to measure leakage current @ 1s
Series
EIA Size
BENEFITS
FEATURES
• Board space savings
• Help protect sensitive electronic circuits against damage from electrostatic discharge (ESD)
• Assist equipment to pass IEC 61000-4-2, level 4 testing
• Thick film technology
• Low capacitance (0.25 pF typical)
• Low trigger voltage
• Low clamping voltage
• Capable of withstanding numerous ESD strikes
• Compatible with standard reflow installation procedures
• Bi-directional protection
• Cellular phones
Caution: This part is not intended to be used under bias, nor for power bus nor data line applications. It is
only to be used in RF applications.
ROHS Compliant
PESD 0402 - 060
Not to be used for new designs. For new design please contact Tyco Electronics Sales
Specification Status: Released
Operating Voltage Designator
6 x 10
Raychem Circuit Protection Products
Overvoltage Protection Device
0
= 6V
ELV Compliant
ESD Protector
DC
PRODUCT: PESD0402-060
DOCUMENT: SCD 26105
REV LETTER: I
REV DATE: DECEMBER 7, 2007
PAGE NO.: 1 OF 8

Related parts for PESD0402-060

PESD0402-060 Summary of contents

Page 1

... PART NUMBERING PESD 0402 - 060 Series Operating Voltage Designator EIA Size The operating voltage is used to measure leakage current @ 1s ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products ELV Compliant PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO ...

Page 2

... C cycle, o 3±1s, 260 C, 2hrs 95% 10s each in coverage X-Y-Z axis I ≤10µA I ≤10µA I ≤10µ PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO Typical Clamping Capacitance 2 Voltage @ 1 MHz, after 60ns 1V rms V Cp C(TLP 60 0.25 Mechanical Solvent ...

Page 3

... Phone: 800-227-4856 www.circuitprotection.com TYPICAL TRANSMISSION LINE PULSE RESPONSE GRAPH 500 450 400 350 300 250 200 150 100 ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products Time (ns) PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO 100 ...

Page 4

... A B Drawing Not To Scale Length A Height B Terminal Width C MAX MIN MAX 1.05 0.28 0.43 (0.041) (0.008) (0.017) (0.004) PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO Width D MIN MAX MIN MAX 0.1 0.3 0.45 0.55 (0.010) (0.018) ...

Page 5

... Main heating ramp up 2 temperature at 200°C Main at 220°C heating at 240°C at 260°C From main heating Cooling temperature to 100°C PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO (Ref) Z Min Max Min Max 0.8 0.9 2 ...

Page 6

... Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com PACKAGING PESD0402-060 ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products Packaging Tape & Reel 10,000 PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO Standard Box 50,000 ...

Page 7

... ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products B C 2.0 ±0.5 13.0±0.5 21.0±0 1.75±0.1 2.0±0.05 4.0±0.1 PRODUCT: PESD0402-060 DOCUMENT: SCD 26105 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO 62.0±1.5 9.0±0.5 13.0±1 1.5±0.1 1.15± ...

Page 8

... For in-line washing, the temperature of the water sprayed should be at 110°C, rinse and drying is done in-line. Warning: Application Limitations for PESD0402-060. This part is not intended to be used under bias, nor for power bus nor data line applications only to be used in RF applications ...