CEM-1206S CUI Inc, CEM-1206S Datasheet - Page 3

BUZZER 2.4KHZ 12MM PC MOUNT

CEM-1206S

Manufacturer Part Number
CEM-1206S
Description
BUZZER 2.4KHZ 12MM PC MOUNT
Manufacturer
CUI Inc
Series
CEMr
Type
Magnetic Transducer, External Driver
Datasheet

Specifications of CEM-1206S

Frequency
2.4kHz
Voltage - Rated
5Vo-p
Current Rating
45mA
Size / Dimension
Circular - 12mm Dia x 9.5mm H
Mounting Type
Through Hole
Sound Pressure Level
85dB
Operating Mode
Continuous
Voltage Range
3 ~ 8Vo-p
Termination
Solder Pins/Posts
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Frequency
-
Other names
102-1155
CEM1206S
SEM-1206S
SEM1206S
Mechanical Characteristics
Item
Solderability
Soldering Heat Resistance
Terminal Mechanical Strength
Vibration
Drop Test
Environment Test
Item
High temp. test
Low temp. test
Thermal shock
Temp./Humidity cycle
Phone: 800.275.4899
Fax: 503.612.2381
Test Condition
Lead terminals are immersed in rosin for 5
seconds and then immersed in solder bath
of 270 ±5°C for 3 ±1 seconds.
Lead terminals are immersed up to 1.5mm from
the buzzer’s body in solder bath of 260 ±5°C for
3 ±1 seconds.
Apply force of 9.8 N (1.0 kg) to the terminal for
10 seconds.
The buzzer will be measured after applying
a vibration amplitude of 1.5 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The part is to be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axis (X, Y, Z) for a total of 9 drops.
Test Condition
The part will be subjected to +85°C for
96 hours.
The part will be subjected to -40°C for
96 hours
The part will be subjected to 10 cycles. One
cycle will consist of:
The part shall be subjected to 10 cycles. One
cycle will be 24 hours and consist of:
Part No: CEM-1206S
Description: magnetic buzzer
www.cui.com
20050 SW 112th Ave.
Evaluation Standard
Evaluation Standard
90% min. of lead terminals should
be wet with solder. (Except the
edge of the terminal)
No in interference in operation.
No damage or cutting off.
After the test, the part should
meet specifications without any
damage to the appearance and
the SPL should be within
±10 dBA of the initial SPL.
After the test, the part shall meet
specifications without any
damage to the appearance and
performance except SPL. After
4 hours at +25°C, the SPL
should be within ±10 dBA of the
initial SPL.
Tualatin, OR 97062
Date: 8/14/2006
Unit: mm
Page No: 3 of 5

Related parts for CEM-1206S