SL1056B Littelfuse Inc, SL1056B Datasheet

GROUND PLATE 20 WAY FOR SL1026

SL1056B

Manufacturer Part Number
SL1056B
Description
GROUND PLATE 20 WAY FOR SL1026
Manufacturer
Littelfuse Inc
Series
SL1056Br
Datasheets

Specifications of SL1056B

Accessory Type
Ground Plate
Termination Style
Screw Terminal
Failsafe Protection Y/n
N
Dimensions
14 mm D x 49 mm L
Mounting Style
Screw
Technology
Mounting Plate Accessory for SL1026 Gas Plasma Arrester
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
GDT; SL1026
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
NOTES:
End of life limits
-- DC: 50% of minimum initial DC breakdown voltage limit to 150% of maximum initial
-- Impulse: less that 150% of initial impulse breakdown voltage limit.
1. Total current through center electrode, tested using SL1053B-NL holder
2. Exceeds capability of SL1053B-NL holder
©2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Refer to www.littelfuse.com/series/SL1026.html for current information.
SL1026-275
SL1026-400
SL1026-700
Part Number*
Agency Approvals
3 Electrode GDT Graphical Symbol
Electrical Characteristics
DC breakdown voltage limit.
AGENCY
®
a
SL1026 Series Gas Plasma Arrester
e
MIN
200
300
560
DC Voltage
100 V/sec
MAX
350
500
840
AGENCY FILE NUMBER
b
E128662
Voltage
1kV/μs
1300
800
900
DC
a = TIP
b = RING
e = GROUND
(centre electrode)
@50-60Hz
Gas Plasma Arrester (GDT) Products
SL1026 Series
9 cycles
Current
(Amps)
1
200
200
200
AC
1 sec x10
Current
(Amps)
Revised: October 23, 2009
50Hz
1
AC
10
10
10
33
• RoHS compliant
• 55 kA surge capability
• 40 kA surge capability
• Will protect against
• Signaling equipment.
• Communication
• Control gear.
8/20μSec
(kAmps)
Features
Current
Description
The SL1026 Series is a heavy-duty transient
suppresser using Gas Plasma technology. In
response to transients that exceed the device's
breakover voltage, the device changes from a very
high impedance state to a low impedance state to
conduct harmful current away from the protected
system. The SL1026 is designed to protect electrical
and electronic equipment such as communications,
control and railway systems. Carefully designed
geometry ensures against short circuiting if a failure
occurs due to conditions and events beyond the
design criteria. Optional electrical mounting clip (part
SL1053 ) is available to aid mounting and connection.
Applications
1
(single shot) tested with
8/20μS pulse as defined
by IEC 61000-4-5
(repetitive)
Trapezoidal waveforms
as specified in RIA 12.
equipment
Surge
x 10
20
20
20
8/20μSec
(kAmps)
1,2
Single
Surge
Max
40
40
40
1
10/350μSec
Max Single
(kAmps)
Surge
8
8
8
• Will protect against
• Will protect against
• Trackside cabinets.
• Cell phone base
capacitor discharge
voltage transient
waveforms as specified
in RIA 12.
double exponential
voltage transient
waveforms as specified
in IEC 571.
stations
1
150(+) and 150(-)
10/1000μSec
(Amps)
200
200
200
SL1026 Series
®

Related parts for SL1056B

SL1056B Summary of contents

Page 1

SL1026 Series Gas Plasma Arrester Agency Approvals AGENCY AGENCY FILE NUMBER E128662 ® 3 Electrode GDT Graphical Symbol a = TIP b = RING GROUND (centre electrode) e Electrical Characteristics DC Voltage 100 V/sec DC Part ...

Page 2

Gas Plasma Arrester (GDT) Products Voltage vs. Time Characteristic Max dynamic breakover voltage Hold-over voltage On-State voltage 0 200 400 600 800 Time (ns) Electrical Specifications Insulation > 10GΩ at 100 Volts Resistance Capacitance: <=2.5pf, 1MHz 0 Volts Bias <150mS, ...