B82442H1475K EPCOS Inc, B82442H1475K Datasheet - Page 7

INDUCTOR 4700UH 50MA 2220 10%

B82442H1475K

Manufacturer Part Number
B82442H1475K
Description
INDUCTOR 4700UH 50MA 2220 10%
Manufacturer
EPCOS Inc
Series
SIMIDr
Type
Ferrite Corer
Datasheets

Specifications of B82442H1475K

Inductance
4.7mH
Current
50mA
Tolerance
±10%
Dc Resistance (dcr)
62.4 Ohm Max
Q @ Freq
30 @ 252kHz
Self Resonant Freq
900kHz
Package / Case
2220 (5750 Metric)
Mounting Type
Surface Mount
Frequency - Test
252kHz
Material - Core
Ferrite Drum
Applications
General Purpose
Inductance Tolerance
± 10%
Dc Resistance Max
62.4ohm
Dc Current Rating
50mA
Resonant Frequency
900kHz
Q @ Vr F
30
Q Test Frequency
2.52MHz
Core Material
Ferrite
Inductor Case
RoHS Compliant
Inductor Case Style
2220
No. Of Pins
2
Svhc
No SVHC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Current - Saturation
-
Current - Temperature Rise
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
495-1794-2
B82442H1475K000

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B82442H1475K000
Manufacturer:
TDK-EPCOS
Quantity:
30 000
Part Number:
B82442H1475K000
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
Disturbed equipment
Electrical devices, equipment and/or systems subject to interference and which can be adversely
affected by it are termed disturbed equipment.
In the same way as interference sources, disturbed equipment can also be categorized correspond-
ing to frequency characteristics. A distinction can be made between narrowband and broadband
susceptibility
Narrowband systems include radio and TV sets, for example, whereas data processing systems are
generally specified as broadband systems.
Radio and TV receivers
Radio reception equipment
Modems
Data transmission systems
Telemetric radio transmission devices
Frequency-coded signalling equipment
Fig. 6
2.3
As previously mentioned, an interference source causes both conducted and radiated electro-
magnetic interference.
Propagation along lines can be detected by measuring the interference current and the interference
voltage
The effect of magnetic and electric interference fields on their immediate vicinity is assessed by
measuring the radiated magnetic and electric field components. This method of propagation is also
frequently termed electric or magnetic coupling (near field).
In higher frequency ranges, characterized by the fact that device dimensions are in the order of
magnitude of the wavelength under consideration, the interference energy is mainly radiated direct-
ly (far field).
Conducted and radiated propagation must also be taken into consideration when measuring the
susceptibility of disturbed equipment.
Interference sources e.g. sine-wave generators as well as pulse generators with a wide variety of
pulse shapes are used for such tests.
General Technical Information
(fig.
Propagation of electromagnetic interference and EMC measurement techniques
Narrowband susceptibility
Disturbed equipment
7).
(fig.
6).
Disturbed equipment (affected by EMI)
15
Digital and analog systems
Data processing systems
Process control computers
Control systems
Video transmission systems
Interface lines
04/00
Broadband susceptibility