B78108S1153K EPCOS Inc, B78108S1153K Datasheet - Page 21

CHOKE RF 15UH 610MA AXIAL

B78108S1153K

Manufacturer Part Number
B78108S1153K
Description
CHOKE RF 15UH 610MA AXIAL
Manufacturer
EPCOS Inc
Series
BCr
Type
Ferrite Corer
Datasheets

Specifications of B78108S1153K

Inductance
15µH
Tolerance
±10%
Current
610mA
Dc Resistance (dcr)
600 mOhm Max
Q @ Freq
60 @ 2.52MHz
Self Resonant Freq
20MHz
Package / Case
Axial
Mounting Type
Through Hole
Frequency - Test
2.52MHz
Material - Core
Ferrite Drum
Applications
General Purpose
Core Material
Ferrite
Dimensions
4 mm Dia. x 9.2 mm L
Test Frequency
2.52 MHz
Maximum Dc Current
610 mAmps
Maximum Dc Resistance
0.6 Ohms
Self Resonant Frequency
610 MHz
Q Minimum
60
Operating Temperature Range
- 55 C to + 125 C
Termination Style
Axial
Inductance Tolerance
± 10%
Dc Resistance Max
0.6ohm
Dc Current Rating
610mA
Q Test Frequency
2.52MHz
Inductor Case Style
Axial Leaded
No. Of Pins
2
Svhc
No SVHC (18-Jun-2010)
Rohs Compliant
Yes
Body Diameter
4mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Current - Saturation
-
Current - Temperature Rise
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
B78108S1153K000
9.4
lEC 60068 -1, Appendix A, defines a method of specifying the climatic category by three groups of
numbers delimited by slash characters.
Example:
– 55 C
+ 85 C
56 days
1st group of numbers:
Absolute value of the lower category temperature T
2nd group of numbers:
Upper category temperature T
3rd group of numbers:
Number of days denoting the test duration for
10
The sizes of surface-mount components
The code differs depending on the standard which it is based on.
The American EIA standards require the length and width to be stated in hundredths of an inch, in
European standards and in the IEC draft standards, these dimensions are encoded in tenths of a
millimeter. The following table sumarizes the sizes:
Length
(mm)
1,0
1,6
2,0
2,5
3,2
4,5
5,6
General Technical Information
0,5
0,8
1,2
2,0
2,5
3,2
5,0
IEC climatic category
Sizes
test Aa (cold) in accordance with IEC 60068-2-1
test Ba (dry heat) in accordance with IEC 60068 -2-2
test duration: 16 h
test Ca (damp heat, steady-state) in accordance with IEC 60068-2-3
at (93 + 2/– 3) % rel. humidity and an ambient temperature of 40 C
width
55/085/56
EIA
0402
0603
0805
1008
1210
1812
2220
max
as test temperature for
29
IEC/EN
1005
1608
2012
2520
3225
4532
5650
min
are encoded using a four-digit coding system.
04/00
as test temperature for

Related parts for B78108S1153K