25ET Cooper/Bussmann, 25ET Datasheet

FUSE 25A 690V BRITISH

25ET

Manufacturer Part Number
25ET
Description
FUSE 25A 690V BRITISH
Manufacturer
Cooper/Bussmann
Series
ETr
Datasheets

Specifications of 25ET

Voltage - Rated
690VAC
Current
25A
Package / Case
Bolt Mount
Size / Dimension
0.673" Dia x 3.032" L (17.10mm x 77.00mm)
Mounting Type
Bolt Mount
Melting I²t
250
Voltage Rating Vdc
690V
Voltage Rating Vac
690V
Fuse Current
25A
Length/height, External
78.2mm
Voltage Ac
690V
Fuse Type
-
Color
-
Operating Temperature
-
Dc Cold Resistance
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Color
-
Fuse Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
25ET
Manufacturer:
BUSSMANN
Quantity:
5 000
Part Number:
25ETS08S
Manufacturer:
IR
Quantity:
20 000
Part Number:
25ETS12SPBF
Manufacturer:
IR
Quantity:
20 000
“F” Range
This is a superior design of fuses in the same physical
package as the “T” range.
Equivalent Ratings
This table shows the suggested equivalent ratings to
replace a “T” with an “F”.
Because of the new design technology it has been possible
to obtain the equivalent energy let-through I
amp rated fuse hence reducing the possibility of premature
operation.
This table gives a range of suggested acceptable new “F”
type to replace the earlier “T” type.
To upgrade your protection to the new “F” series select a
fuse rating within the range shown that suits your circuit
inrush requirements. You will still have the same or better
protection of your semiconductor devices.
It should be remembered that to protect devices we must
consider the energy let-through of the selected fuse. The
label amp rating will relate to the full load current and the
circuit inrush amps.
The suggested replacements are based on:
This gives enhanced reliability due to the use of a higher
current rated fuse which avoids nuisance operation and still
gives improved short-circuit protection.
84
The Edison British Style semiconductor protection fuses
include a 660VAC line utilizing new filler technology. These
new fuses have greatly reduced peak let-through current
and energy under fault conditions and hence extend fuse
protection capability. They can be recognized by the letter
“F” in their catalog number. Application and technical data
for these 660VAC “F” fuses and the original line of 240VAC
British “T” type fuses are presented on the following pages.
a. Similar surge withstand to normal circuit overloads.
b. Lower total I
2
t let-through.
2
t with a higher
Replacement Table — “T” to “F” (660V)
Earlier
“T” Range
6CT
10CT
12CT
16CT
20CT
25ET
32ET
35ET
40ET
45ET
56ET
63ET
80ET
65EET
75EET
90EET
110EET
140EET
160EET
160MT
180MT
200MT
250MT
280MT
315MT
355MT
180MMT
200MMT
225MMT
280MMT
315MMT
355MMT
400MMT
450MMT
500MMT
560MMT
630MMT
710MMT
SEMICONDUCTOR PROTECTION FUSES
New “F” Range
Lowest
Rating
6FC
10FC
12FC
16FC
20FC
35FE
35FE
40FE
45FE
63FE
63FE
80FE
140FEE
160FEE
200FM
225FM
250FM
280FM
315FM
350FM
350FM
350MT
180FM
200FM
225FM
280FM
315FM
350FM
500FMM
550FMM
630FMM
700FMM
700FMM
700FMM
BRITISH STYLE–
Highest
Rating
6FC
10FC
12FC
16FC
20FC
35FE
40FE
45FE
50FE
63FE
71FE
80FE
90FE
100FE
100FEE
120FEE
140FEE
160FEE
180FEE
200FEE
180FM
200FM
225FM
250FM
280FM
315FM
350FM
350FM
350FM
180FM
200FM
225FM
280FM
315FM
350FM
400FMM
450FMM
500FMM
550FMM
630FMM
700FMM
700FMM
700FMM

Related parts for 25ET

25ET Summary of contents

Page 1

... SEMICONDUCTOR PROTECTION FUSES Replacement Table — “T” to “F” (660V) Earlier “T” Range 6CT 10CT 12CT 16CT 20CT 25ET 32ET 35ET 40ET 45ET 56ET 63ET – – 80ET 65EET t with a higher ...

Page 2

... SEC) Part Clearing Clearing Number Pre-arc At 415V At 660V 6FC 1 10FC 12FC 16FC 20FC 30 100 160 25ET 25 150 250 32ET 32 190 350 35FE 33 130 200 40FE 52 180 300 45FE 76 270 450 50FE 103 380 600 63FE 135 480 750 71FE 210 600 ...

Page 3

... Interrupting rating 200kA RMS Symmetrical. • Watts loss provided at rated current. • All fuses above have been tested to 318VAC. • These fuses meet the requirements Part 4 and IEC 269-4 • UL Recognition on LET and LMT. Others pending – Consult Edison. 86 SEMICONDUCTOR PROTECTION FUSES ...

Page 4

... Type 74.6 64.3 LCT & 63.5 LET 56 41.8 FEE & EET 113 80-85 LMT 84 59 FMM 113 80-85 LMMT & LCT FM & LMT SEMICONDUCTOR PROTECTION FUSES 54.8 8.7 8.7 28 8.4 8.7 48 17.7 19.1 26.2 17.7 19 41 FE, ET & LET BRITISH STYLE– ...

Page 5

... CURRENT IN AMPERES 660V Time-Current Curves FC (6-20A) FE (35-100A) FM (180-350A) 88 SEMICONDUCTOR PROTECTION FUSES AMPERE RATING 660V Time-Current Curves FEE (100-200A) FMM (400-700A CURRENT IN AMPERES BRITISH STYLE– AMPERE RATING ...

Page 6

... CURRENT IN AMPERES 240V Time-Current Curves LCT (6-20A) LET (25-180A) LMMT (400-900A) SEMICONDUCTOR PROTECTION FUSES AMPERE RATING 240V Time-Current Curves LMT (160-450A .01 .004 CURRENT IN AMPERES BRITISH STYLE– AMPERE RATING 89 ...

Page 7

Indicator System Trip-Indicators Trip-indicators are available for use in parallel with the main fuse. They can either be attached to the associated fuse or mounted separately in panel mounted fuse clips, reference CL1. A push-on adapter and microswitch attachment is ...