PIC16F84A-04/SS Microchip Technology, PIC16F84A-04/SS Datasheet - Page 267

IC MCU FLASH 1KX14 EE 20SSOP

PIC16F84A-04/SS

Manufacturer Part Number
PIC16F84A-04/SS
Description
IC MCU FLASH 1KX14 EE 20SSOP
Manufacturer
Microchip Technology
Series
PIC® 16Fr

Specifications of PIC16F84A-04/SS

Core Size
8-Bit
Program Memory Size
1.75KB (1K x 14)
Core Processor
PIC
Speed
4MHz
Peripherals
POR, WDT
Number Of I /o
13
Program Memory Type
FLASH
Eeprom Size
64 x 8
Ram Size
68 x 8
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Package / Case
20-SSOP
Controller Family/series
PIC16F
No. Of I/o's
13
Eeprom Memory Size
64Byte
Ram Memory Size
68Byte
Cpu Speed
4MHz
No. Of Timers
1
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
XLT20SS1-1 - SOCKET TRANSITION 20DIP 20SSOPI3-DB16F84A - BOARD DAUGHTER ICEPIC3AC164307 - MODULE SKT FOR PM3 28SSOPAC164018 - MODULE SKT PROMATEII 20SSOP
Data Converters
-
Connectivity
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
16.4.1
1997 Microchip Technology Inc.
Slave Mode
In slave mode, the SCL and SDA pins must be configured as inputs (TRIS bits set). The SSP
module will override the input state with the output data when required (slave-transmitter).
When an address is matched or the data transfer after an address match is received, the hard-
ware automatically will generate the acknowledge (ACK) pulse, and then load the SSPBUF reg-
ister with the received value currently in the SSPSR register.
There are certain conditions that will cause the SSP module not to give this ACK pulse. These
are if either (or both):
a)
b)
In this case, the SSPSR register value is not loaded into the SSPBUF, but bit SSPIF and SSPOV
bits are set.
tus of the BF and SSPOV bits. The shaded cells show the condition where user software did not
properly clear the overflow condition. The BF flag bit is cleared by reading the SSPBUF register
while the SSPOV bit is cleared through software.
The SCL clock input must have a minimum high and low time for proper operation. The high and
low times of the I
parameter 100
The buffer full bit, BF (SSPSTAT<0>), was set before the transfer was received.
The overflow bit, SSPOV (SSPCON<6>), was set before the transfer was received.
Table 16-2
and
2
C specification as well as the requirement of the SSP module are given in
parameter 101
shows what happens when a data transfer byte is received, given the sta-
of the
“Electrical Specifications”
Section 16. BSSP
section.
DS31016A-page 16-17
16

Related parts for PIC16F84A-04/SS