PIC18LF2480-I/ML Microchip Technology, PIC18LF2480-I/ML Datasheet - Page 8

IC PIC MCU FLASH 8KX16 28QFN

PIC18LF2480-I/ML

Manufacturer Part Number
PIC18LF2480-I/ML
Description
IC PIC MCU FLASH 8KX16 28QFN
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18LF2480-I/ML

Core Size
8-Bit
Program Memory Size
16KB (8K x 16)
Core Processor
PIC
Speed
40MHz
Connectivity
CAN, I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, HLVD, POR, PWM, WDT
Number Of I /o
25
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
2 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Controller Family/series
PIC18
No. Of I/o's
25
Eeprom Memory Size
256Byte
Ram Memory Size
768Byte
Cpu Speed
40MHz
No. Of Timers
4
Processor Series
PIC18LF
Core
PIC
Data Bus Width
8 bit
Data Ram Size
768 B
Interface Type
SPI, I2C, EUSART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
25
Number Of Timers
4
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000, ICE4000, DM163011, DV164136
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
PIC18F2480/2580/4480/4580
7. Module: ECAN™ Technology
8. Module: ECAN Technology
DS80496C-page 8
Under specific conditions, the first five bits of a
transmitted identifier may not match the value in
the Transmit Buffer ID register, TXBnSIDH. The
following conditions must exist for the corruption
to occur:
• A transmit message must be pending
• The ECAN module must detect a
Work around
None.
Affected Silicon Revisions
The Error Interrupt Flag, ERRIF (PIR3<5>), may
not be able to be cleared in software after either
of the following counter registers exceeds 127:
• Transmit Error Counter Register (TXERRCNT)
• Receive Error Counter Register (RXERRCNT)
Work around
Monitor the EWARN (COMSTAT<0>) bit to
determine if either the TXERRCNT or the
RXERRCNT exceeds 95 and clear the ERRIF
flag before either counter reaches 127.
Affected Silicon Revisions
A1
A1
Start-of-Frame (SOF) in the third bit of the
interframe space.
X
X
B0
B0
B2
B2
9. Module: ECAN Technology
Following an error on the bus, the ECAN module
is unable to switch from Listen Only mode
directly to Configuration mode.
Work around
Use the REQOP (CANCON<7:5>) bits to select
Normal mode as an intermediate step when
switching from Listen Only mode to Configuration
mode.
Affected Silicon Revisions
A1
X
B0
B2
 2010 Microchip Technology Inc.