Z8F042AHJ020SC Zilog, Z8F042AHJ020SC Datasheet - Page 44

IC ENCORE XP MCU FLASH 4K 28SSOP

Z8F042AHJ020SC

Manufacturer Part Number
Z8F042AHJ020SC
Description
IC ENCORE XP MCU FLASH 4K 28SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F042AHJ020SC

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
23
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Eeprom Size
128 x 8
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
28-SSOP
Processor Series
Z8F042xx
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
1 KB
Interface Type
UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
23
Number Of Timers
16 Bit
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 8 Channel
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3371

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F042AHJ020SC
Manufacturer:
Maxim
Quantity:
375
Low-Power Modes
STOP Mode
PS022825-0908
The Z8 Encore! XP F082A Series products contain power-saving features. The
highest level of power reduction is provided by the STOP mode, in which nearly all device
functions are powered down. The next lower level of power reduction is provided by the
HALT mode, in which the CPU is powered down.
Further power savings can be implemented by disabling individual peripheral blocks
while in Active mode (defined as being in neither STOP nor HALT mode).
Executing the eZ8 CPU’s STOP instruction places the device into STOP mode, powering
down all peripherals except the Voltage Brownout detector, the Low-power Operational
Amplifier and the Watchdog Timer. These three blocks may also be disabled for additional
power savings. Specifically, the operating characteristics are:
To minimize current in STOP mode, all GPIO pins that are configured as digital inputs
must be driven to one of the supply rails (V
ured as outputs must also be driven to one of the supply rails. The device can be brought
out of STOP mode using Stop Mode Recovery. For more information on Stop Mode
Recovery, see
Primary crystal oscillator and internal precision oscillator are stopped; XIN and
XOUT (if previously enabled) are disabled, and PA0/PA1 revert to the states
programmed by the GPIO registers.
System clock is stopped.
eZ8 CPU is stopped.
Program counter (PC) stops incrementing.
Watchdog Timer’s internal RC oscillator continues to operate if enabled by the
Oscillator Control register.
If enabled, the Watchdog Timer logic continues to operate.
If enabled for operation in STOP mode by the associated Flash Option Bit, the
Voltage Brownout protection circuit continues to operate.
Low-power operational amplifier continues to operate if enabled by the Power
Control register to do so.
All other on-chip peripherals are idle.
Reset, Stop Mode Recovery, and Low Voltage Detection
CC
or GND). Additionally, any GPIOs config-
Z8 Encore! XP
Product Specification
on page 23.
®
Low-Power Modes
F082A Series
33

Related parts for Z8F042AHJ020SC