Specifications of Z16F2810VH20EG

Core Processor
ZNEO
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
46
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
68-LCC (J-Lead)
Data Bus Width
16 bit
Data Ram Size
4 B
Interface Type
ESPI, I2C, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
46
Number Of Timers
4
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 12 Channel
For Use With
770-1003 - ISP 4PORT FOR ZILOG ZNEO MCU269-4537 - DEV KIT FOR Z16F ZNEO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4691-5
Z16F2810VH20EG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16F2810VH20EG
Manufacturer:
Zilog
Quantity:
151
Part Number:
Z16F2810VH20EG
Manufacturer:
Zilog
Quantity:
10 000
PS022008-0810
Bit Position
[6]
TPOL
Value (H) Description
Timer Input/Output Polarity
This bit is a fu nction of the cur rent operating mode of the timer. It
determines the polarity of the input and/or output signal. When the timer is
disabled, the timer output signal is set to the value of this bit.
ONE-SHOT mode —If the timer is enabled, the timer output signal pulses
(changes state) for one system clock cycle after timer Reload.
CONTINUOUS mode—If the timer is enabled, the timer output signal is
complemented after timer Reload.
COUNTER mode—If the timer is enabled, the timer output signal is
complemented after timer reload.
0 = Count occurs on the rising edge of the timer input signal.
1 = Count occurs on the falling edge of the timer input signal.
PWM SINGLE OUTPUT mode—When enabled, the timer output is forced
to TPOL after PWM count match and forced back to TPOL after Reload.
CAPTURE mode—If the timer is enabled, the timer output signal is
complemented after timer Reload.
0 = Count is captured on the rising edge of the timer input signal.
1 = Count is captured on the falling edge of the timer input signal.
COMPARE mode—The timer output signal is complemented after timer
Reload.
GATED mode—The timer output signal is complemented after timer
Reload.
0 = Timer counts when the timer input signal is High and interrupts are
generated on the falling edge of the timer input.
1 = Timer counts when the timer input signal is Low and interrupts are
generated on the rising edge of the timer input.
CAPTURE/COMPARE mode—If the timer is enabled, the timer output
signal is complemented after timer Reload.
0 = Counting starts on the first rising edge of the timer Input signal. 
The current count is captured on subsequent rising edges of the timer 
input signal.
1 = Counting starts on the first falling edge of the timer input signal. 
The current count is captured on subsequent falling edges of the timer
input signal.