Z8F2422AR020SG Zilog, Z8F2422AR020SG Datasheet
Z8F2422AR020SG
Specifications of Z8F2422AR020SG
Z8F2422AR020SG
Available stocks
Related parts for Z8F2422AR020SG
Z8F2422AR020SG Summary of contents
Page 1
... The errata listed in Table 1 are found in Zilog’s Z8 Encore! XP 0344 to 0519, where the date code is YYWW (year and week of assembly). Date codes 0442 to 0519 are mixed; the errata will apply to some units, but not others. These errata are NOT APPLICABLE to date codes 0520 and later ...
Page 2
Z8 Encore! XP F64XX Series with Date Codes Prior to 0344 The errata listed in Table 2 are found in the production Z8 Encore! XP codes prior to 0344, where the date code is YYWW (year and week of ...
Page 3
Table 2. Z8 Encore! XP F64XX Series Errata Date Coded Prior to 0334 (Continued) Sl No. Summary Description 4 UART address com- Setting bit 7 (MPMD[1]) of the UART control 1 register to 1 does not produce pare function does ...
Page 4
Table 2. Z8 Encore! XP F64XX Series Errata Date Coded Prior to 0334 (Continued) Sl No. Summary Description 11 RESET pin is not fil- The RESET pin does not properly filter the input signal. The device may enter tered. Reset ...
Page 5
... TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. Z8, Z8 Encore!, and Z8 Encore! XP are registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. ...