ST10F276-6Q3 STMicroelectronics, ST10F276-6Q3 Datasheet - Page 36

no-image

ST10F276-6Q3

Manufacturer Part Number
ST10F276-6Q3
Description
MCU 16BIT 832K FLASH 144-PQFP
Manufacturer
STMicroelectronics
Series
ST10r
Datasheet

Specifications of ST10F276-6Q3

Core Processor
ST10
Core Size
16-Bit
Speed
64MHz
Connectivity
ASC, CAN, EBI/EMI, I²C, SSC, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
111
Program Memory Size
832KB (832K x 8)
Program Memory Type
FLASH
Ram Size
68K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 24x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
144-MQFP, 144-PQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Internal Flash memory
4.3.12
36/231
Table 17.
XFlash interface control register
This register is used to configure the XFLASH interface behavior on the XBUS. It allows to
set the number of wait states introduced on the XBUS before the internal READY signal is
given to the ST10 bus master.
XFICR (0xE E000h)
Table 18.
15
WS(3:0)
SEQER
RESER
WPF
Bit
Bit
14
Flash error register (continued)
XFlash interface control register
13
Sequence error
This bit is automatically set when the control registers (FCR1H/L-FCR0H/L, FARH/L,
FDR1H/L-FDR0H/L) are not correctly filled to execute a valid write operation. in this
case no write operation is executed. This bit has to be software reset.
Resume error
This bit is automatically set when a suspended program or erase operation is not
resumed correctly due to a protocol error. In this case the suspended operation is
aborted. This bit has to be software reset.
Write protection flag
This bit is automatically set when trying to program or erase in a sector write
protected. In case of multiple sector erase, the not protected sectors are erased, while
the protected sectors are not erased and bit WPF is set. This bit has to be software
reset.
Wait state setting
These three bits are the binary coding of the number of wait states introduced by the
XFLASH interface through the XBUS internal READY signal. Default value after reset
is 1111, that is the up to 15 wait states are set. The following recommendations for the
ST10F276E are hereafter reported:
For f
For f
CPU
CPU
12
> 40MHz1 Wait-StateWS(3:0) = ‘0001’
≤ 40MHz0 Wait-StateWS(3:0) = ‘0000’
11
10
Reserved
9
XBUS
8
Function
7
Function
6
5
4
WS3
RW
3
Reset value: 000Fh
WS2
RW
2
ST10F276E
WS1
RW
1
WS0
RW
0