Specifications of SAK-XC164CS-16F40F BB

Core Processor
C166SV2
Core Size
16-Bit
Speed
40MHz
Connectivity
CAN, EBI/EMI, SPI, UART/USART
Peripherals
PWM, WDT
Number Of I /o
79
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.35 V ~ 2.7 V
Data Converters
A/D 14x8/10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
100-LFQFP
Data Bus Width
16 bit
Data Ram Size
8 KB
Interface Type
ASC, CAN, SSC
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
79
Number Of Timers
5
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 14 Channel
Packages
PG-TQFP-100
Max Clock Frequency
40.0 MHz
Sram (incl. Cache)
8.0 KByte
Can Nodes
2
A / D Input Lines (incl. Fadc)
14
Program Memory
128.0 KByte
For Use With
B158-H8962-X-X-7600IN - KIT EASY XC164CSMCBX167-NET - BOARD EVAL INFINEON CAN/ETHRNTMCBXC167-BASIC - BOARD EVAL BASIC INFINEON XC16X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
KX164CS16F40FBBNT
KX164CS16F40FBBXT
SAKXC164CS16F40FBBT
SP000083674
SP000224560
4.4
4.4.1
The internal operation of the XC164CS is controlled by the internal master clock
The master clock signal
different mechanisms. The duration of master clock periods (TCMs) and their variation
(and also the derived external timing) depend on the used mechanism to generate
This influence must be regarded when calculating the timings for the XC164CS.
Figure 15
Note: The example for PLL operation shown in
The used mechanism to generate the master clock is selected by register PLLCON.
Data Sheet
the example for prescaler operation refers to a divider factor of 2:1.
Phase Locked Loop Operation (1:N)
f
f
Direct Clock Drive (1:1)
f
f
Prescaler Operation (N:1)
f
f
OSC
MC
OSC
MC
OSC
MC
AC Parameters
Definition of Internal Timing
Generation Mechanisms for the Master Clock
f
MC
can be generated from the oscillator clock signal
62
Figure 15
refers to a PLL factor of 1:4,
TCM
Electrical Parameters
TCM
TCM
MCT05555
Derivatives
V2.3, 2006-08
XC164CS
f
OSC
f
MC
f
.
MC
via
.