HCPL-7800-000E Avago Technologies US Inc., HCPL-7800-000E Datasheet

OPTOCOUPLER AMP 100KHZ 8-DIP

HCPL-7800-000E

Manufacturer Part Number
HCPL-7800-000E
Description
OPTOCOUPLER AMP 100KHZ 8-DIP
Manufacturer
Avago Technologies US Inc.
Type
General Purposer
Datasheets

Specifications of HCPL-7800-000E

Package / Case
8-DIP (0.300", 7.62mm)
Amplifier Type
Isolation
Number Of Circuits
1
-3db Bandwidth
100kHz
Current - Input Bias
500nA
Voltage - Input Offset
300µV
Current - Supply
10.9mA
Current - Output / Channel
16mA
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Number Of Channels
Single
Common Mode Rejection Ratio (min)
76 dB
Available Set Gain
18.31 dB
Input Offset Voltage
2 mV
Operating Supply Voltage
5 V
Supply Current
16 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
Through Hole
Supply Voltage (max)
5.5 V
Supply Voltage (min)
4.5 V
Bandwidth
100 kHz
Common Mode Rejection Ratio
76
Current, Supply
10.86 mA (Input), 11.56 mA (Output)
Package Type
DIP-8
Power Dissipation
600 mW
Propagation Delay
4.99 μs
Slew Rate
10
Temperature, Operating, Range
-40 to +85 °C
Time, Fall
2.96 μs
Time, Rise
2.96 μs
Voltage, Gain
8 V/V
Voltage, Input
2 V
Voltage, Input Offset
0.3 mV
Voltage, Noise
31.5 mV
Voltage, Supply
5.5 V
No. Of Channels
1
Isolation Voltage
3.75kV
Optocoupler Output Type
Analog
Input Current
16mA
Output Voltage
3.8V
Opto Case Style
DIP
No. Of Pins
8
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Slew Rate
-
Gain Bandwidth Product
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
516-1481-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-7800-000E
Manufacturer:
AVAGO
Quantity:
1 800
Part Number:
HCPL-7800-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-7800-000E
Quantity:
7 080
Part Number:
HCPL-7800-000E/HCPL7800-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
The HCPL-7800 isolation amplifier family was
designed for current sensing in electronic motor drives.
In a typical implementation, motor currents flow
through an external resistor and the resulting analog
voltage drop is sensed by the HCPL-7800. A
differential output voltage is created on the other side
of the HCPL-7800 optical isolation barrier. This
differential output voltage is proportional to the motor
current and can be converted to a single-ended signal
by using an op-amp. Since common-mode voltage
swings of several hundred volts in tens of
nanoseconds are common in modern switching
inverter motor drives, the HCPL-7800 was designed to
ignore very high common-mode transient slew rates
(of at least 10 kV/ms).
The high CMR capability of the HCPL-7800 isolation
amplifier provides the precision and stability needed to
accurately monitor motor current in high noise motor
control environments, providing for smoother control
(less "torque ripple") in various types of motor control
applications.
The product can also be used for general analog
signal isolation applications requiring high accuracy,
stability, and linearity under similarly severe noise
conditions. For general applications, we recommend
the HCPL-7800 (gain tolerance of /- 3%). The HCPL-
7800 utilizes sigma delta (S-D) analog-to-digital
converter technology, chopper stabilized amplifiers,
and a fully differential circuit topology.
Together, these features deliver unequaled isolation-
mode noise rejection, as well as excellent offset and
gain accuracy and stability over time and temperature.
This performance is delivered in a compact, auto-
insertable, industry standard 8-pin DIP package that
meets worldwide regulatory safety standards. (A gull-
wing surface mount option #300 is also available).
Products
HCPL-7800
Isolation Amplifier
Description
Features
15 kV/us Common-Mode Rejection at VCM = 1000 V
Compact, Auto-Insertable Standard 8-pin DIP Package
0.00025 V/V/ degrees C Gain Drift vs. Temperature
0.3 mV Input Offset Voltage
100 kHz Bandwidth
0.004% Nonlinearity
Worldwide Safety Approval:
UL 1577 (3750 Vrms/1 min.), CSA and IEC/EN/DIN EN 60747-5-2
Advanced Sigma-Delta (S-D) A/D Converter Technology
Fully Differential Circuit Topology
Options available are:
>
Optocouplers - Plastic
>
Plastic Miniature Isolation Amplifier
Lifecycle status:
>
HCPL-7800
Active

Related parts for HCPL-7800-000E

HCPL-7800-000E Summary of contents

Page 1

... For general applications, we recommend the HCPL-7800 (gain tolerance of /- 3%). The HCPL- 7800 utilizes sigma delta (S-D) analog-to-digital converter technology, chopper stabilized amplifiers, and a fully differential circuit topology. ...

Page 2

Isolation Amplifier 300 = Surface Mount Option 500 = Tape and Reel Packaging Option Applications Motor Phase and Rail Current Sensing Inverter Current Sensing Switched Mode Power Supply Signal Isolation General Purpose Current Sensing and Monitoring General Purpose Analog Signal ...

Page 3

... HCPL-7800(A). A differential output voltage is created on the other side of the HCPL-7800(A) optical isolation barrier. This differential output voltage is pro- portional to the motor current and can be converted to a single-ended signal by using an op-amp as shown in the recommended application circuit ...

Page 4

... MAX. 3.56 ± 0.13 (0.140 ± 0.005) 1.080 ± 0.320 (0.043 ± 0.013) Note: Initial or continued variation in the color of the HCPL-7800(A)’s white mold compound is normal and does not affect device performance or reliability.  Surface Gull Package Mount Wing ...

Page 5

Gull Wing Surface Mount Option 300 9.80 ± 0.25 (0.386 ± 0.010 7800 YYWW 1 2 1.19 (0.047) MAX. 1.080 ± 0.320 (0.043 ± 0.013) 2.54 (0.100) BSC DIMENSIONS IN MILLIMETERS (INCHES). TOLERANCES (UNLESS OTHERWISE SPECIFIED): NOTE: ...

Page 6

... Regulatory Information The HCPL-7800(A) has been approved by the following organizations: IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2): 2003-01. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage 300 Vrms ...

Page 7

Insulation and Safety Related Specifications Parameter Minimum External Air Gap (Clearance) Minimum External Tracking (Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) Isolation Group Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Supply Voltage Steady-State Input ...

Page 8

... Min./Max. specifications are within the Recommended Operating Conditions. DD2 A Parameter Symbol Input Offset Voltage V OS Magnitude of Input Offset |DV /DT OS Change vs. Temperature Gain (HCPL-7800A Gain (HCPL-7800 Magnitude of V |DG/DT OUT Gain Change vs.Temperature V 200 mV Nonlinearity NL OUT 200 Magnitude of V |dNL OUT 200 200 mV Nonlinearity Change vs ...

Page 9

AC Electrical Specifications Unless otherwise noted, all typicals and figures are at the nominal operating conditions and T = 25°C; all Min./Max. specifications are within the Recommended Operating Conditions. DD2 A Parameter Symbol Min. ...

Related keywords