HCPL-7800A#500 Avago Technologies US Inc., HCPL-7800A#500 Datasheet - Page 18

no-image

HCPL-7800A#500

Manufacturer Part Number
HCPL-7800A#500
Description
OPTOCOUPLER AMP 100KHZ TOL 8-SMD
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-7800A#500

Amplifier Type
Isolation
Number Of Circuits
1
-3db Bandwidth
100kHz
Current - Input Bias
500nA
Voltage - Input Offset
300µV
Current - Supply
10.9mA
Current - Output / Channel
16mA
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SMD Gull Wing
No. Of Amplifiers
1
Isolation Voltage
3750Vrms
Gain Non-linearity Max
0.004%
Slew Rate
10kV/us
Supply Voltage Range
4.5V To 5.5V
Input Offset Voltage
2mV
Bandwidth
100kHz
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Output Type
-
Gain Bandwidth Product
-
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HCPL-7800A#500HCPL-7800A
Manufacturer:
AVAGO
Quantity:
21 000
Company:
Part Number:
HCPL-7800A#500HCPL-7800A
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-7800A#500
Manufacturer:
AGILENT
Quantity:
8 000
Company:
Part Number:
HCPL-7800A#500HCPL-7800A-000E
Manufacturer:
AVAGO
Quantity:
3 000
Company:
Part Number:
HCPL-7800A#500HCPL-7800A-000E
Manufacturer:
AVAGO
Quantity:
1 100
4.2: Does the gain change if the internal LED light output
degrades with time?
No. The LED is used only to transmit a digital pattern.
Avago Technologies has accounted for LED degradation
in the design of the product to ensure long life.
5. POWER SUPPLIES AND START-UP
5.1: What are the output voltages before the input side
power supply is turned on?
V
is close to 1.29 V and V
is close to 3.80 V. This is
O+
O-
equivalent to the output response at the condition that
LED is completely off.
5.2: How long does the HCPL-7800(A) take to begin work-
ing properly after power-up?
Within 1 ms after V
and V
powered the device
DD1
DD2
starts to work. But it takes longer time for output to settle
down completely. In case of the offset measurement
while both inputs are tied to ground there is initially V
OS
adjustment (about 60 ms). The output completely settles
down in 100 ms after device powering up.
6. MISCELLANEOUS
6.1: How does the HCPL-7800(A) measure negative signals
with only a +5 V supply?
The inputs have a series resistor for protection against
large negative inputs. Normal signals are no more than
200 mV in amplitude. Such signals do not forward bias
any junctions sufficiently to interfere with accurate
operation of the switched capacitor input circuit.
www.avagotech.com
For product information and a complete list of distributors, please go to our web site:
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies Limited in the United States and other countries.
Data subject to change. Copyright © 00-00 Avago Technologies Limited. All rights reserved. Obsoletes -EN
AV0-00EN - May , 00