MAX6754UKTD3+T Maxim Integrated Products, MAX6754UKTD3+T Datasheet - Page 9

IC DETECT VOLT WINDOW SOT23-5

MAX6754UKTD3+T

Manufacturer Part Number
MAX6754UKTD3+T
Description
IC DETECT VOLT WINDOW SOT23-5
Manufacturer
Maxim Integrated Products
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of MAX6754UKTD3+T

Number Of Voltages Monitored
1
Output
Push-Pull, Totem Pole
Reset
Active Low
Reset Timeout
100 ms Minimum
Voltage - Threshold
3.3V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
SOT-23-5, SC-74A, SOT-25
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MAX6754UKTD3+T
MAX6754UKTD3+TTR
MAX6754/
MAX6755/
MAX6756
1
2
3
4
5
MAX6757/
MAX6758/
MAX6759
1
2
3
6
4
5
_______________________________________________________________________________________
Low-Power, Single/Dual-Voltage Window
PIN
MAX6760/
MAX6761/
MAX6762
1
2
8
4
6
3
5
MAX6763/
MAX6764
1
2
5
RESET/
RESET
NAME
V
GND
V
SET
UV/
MR
UV
OV
CC2
CC
Power Voltage Input. V
voltage.
Power Input. V
Ground
Active-Low Manual Reset Input. Drive MR low to assert undervoltage
and reset outputs. The asserted output remains asserted for the
specified propagation delay period after MR goes high. MR is internally
pulled up to V
Reset Output. The Reset Output asserts when V
selected UV
output deasserts after the specified timeout period after V
above the UV
MAX6754: Active-low push-pull output (RESET).
MAX6755: Active-high push-pull output (RESET).
MAX6756: Active-low open-drain output (RESET).
Threshold Window Select Input. SET configures the undervoltage and
overvoltage window range for the internal detectors. Connect SET to
GND for ±5% window, or to V
for a ±15% window.
Undervoltage Output. UV/UV asserts when the monitored
supply/supplies are below the UV
deasserts after the specified timeout period when the monitored
supply/supplies rise above the UV
propagation delay after MR goes high.
MAX6757/MAX6760: Active-low push-pull output (UV).
MAX6758/MAX6761: Active-high push-pull output (UV).
MAX6759/MAX6762: Active-low open-drain output (UV).
V
device output power supply when V
Active-Low Overvoltage Output. OV asserts low when the monitored
supply/supplies are above their overvoltage threshold (OV
high impedance immediately when the monitored supply/supplies drop
below OV
There is no timeout delay period for the OV output.
For MAX6763/MAX6764, OV is low when OVIN is above the internal
0.5V threshold. OV is high when OVIN is below the internal 0.5V
threshold.
MAX6757–MAX6762: Active-low open-drain output.
MAX6763: Active-low push-pull output.
MAX6764: Active-low open-drain output.
CC2
Voltage Input. Input for the second window voltage monitor, and
TH
TH
.
TH
CC
CC
threshold or above the selected OV
threshold or drops below the OV
through a 26kΩ resistor.
powers the device.
CC
powers the device. V
CC
FUNCTION
for ±10% window. Bias SET to V
TH
TH
CC2
thresholds or MR is low. UV/UV
thresholds or for the specified
> V
CC
Pin Description
Detectors
.
CC
CC
TH
is the monitored
TH
is below the
threshold.
threshold. Reset
CC
TH
). OV goes
rises
CC
/2
9

Related parts for MAX6754UKTD3+T