EC90X EPCOS Inc, EC90X Datasheet

SURGE ARRESTER 90V GASTUBE 2PIN

EC90X

Manufacturer Part Number
EC90X
Description
SURGE ARRESTER 90V GASTUBE 2PIN
Manufacturer
EPCOS Inc
Series
ECr
Datasheets

Specifications of EC90X

Spark Over Voltage
90V
Tolerance
±20%
Impulse Discharge Current
5.0kA 8x20µs
Package / Case
Axial
Mounting Type
Through Hole
Peak Pulse Current
10 KA
Dc Breakover Voltage (nominal)
90 V
Number Of Electrodes
2
Termination Style
Axial
Failsafe Protection Y/n
N
Mounting Style
Through Hole
Technology
Surge Arrester
Suppressor Type
Gas Discharge
Impulse Sparkover Voltage
600V
Svhc
No SVHC (18-Jun-2010)
Capacitance
2pF
Discharge Current Ac Max
5kA
Impulse Discharge Current Max
5kA
Rohs Compliant
Yes
Insulation Resistance
10Gohm
Dc Breakover Voltage
90V
Gdt Case Style
Axial Leaded
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
495-1476
B88069X 720S102
B88069X0720S102
B88069X720S102

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EC90X
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
Part Number:
EC90XG
Manufacturer:
Litteifuse
0
DC spark-over voltage
Impulse spark-over voltage
Nominal impulse discharge current (wave 8/20 µs)
Single impulse discharge current
Nominal alternating discharge current (50 Hz, 1 s)
Alternating discharge current (50 Hz, 9 cycles)
Insulation resistance at 50 V
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, red
1)
2)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
AB E / AB PM
Surge Arrester
2-Electrode-Arrester
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
at 100 V/µs
at 1 kV/µs
1) 2)
- for 99 % of measured values
- typical values of distribution
- for 99 % of measured values
- typical values of distribution
dc
(wave 8/20 µs)
Page 1 of 2
Ordering code:
90
< 500
< 450
< 600
< 550
5
10
5
20
> 10
< 1
~ 12
~ 0.8
~ 80
~ 1.5
-40 ... +90
40/ 90/ 21
EC
90
YY
O
± 20
- Series
- Nominal voltage
- Year of production
- Non radioactive
EC 90 YY O
B88069X0720S102
Issue 04, 18.04.2002
EC90X
V
%
V
V
V
V
kA
kA
A
A
GΩ
pF
V
A
V
g
°C

Related parts for EC90X

EC90X Summary of contents

Page 1

... In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845 Ordering code: 90 < 500 < 450 < 600 < 550 5 (wave 8/20 µ > 10 < 0 1.5 -40 ... +90 40/ 90 Page EC90X B88069X0720S102 V ± GΩ ° Series - Nominal voltage - Year of production - Non radioactive Issue 04, 18.04.2002 ...

Page 2

... Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed Ordering code: Not to scale Dimensions in mm Non controlled document Page EC90X B88069X0720S102 Issue 04, 18.04.2002 ...