Impulse Transverse Delay .............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 10
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ........................................................................................................................... < 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage
Impulse Discharge Current ...........................................40000 A, 8/20 µs
Alternating Discharge Current ......................................130 Arms, 11 cycles
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) ....................................................................................................................
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD
• Sparkover limits after life ±25 %, IR >10
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1
2
3
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
Tube meets BT requirement Type 14 A/1 (210-310 V).
Network applied.
DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
Characteristics
100 V/µs
1000 V/µs
100 V/µs
1000 V/µs
2
.................................................>135 V, (52 V for Model 2026-07 & 2026-09, ........... < 150 ms
8
Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
2026-07
®
275 V
700 V
Gas Discharge Tubes is the total current equally divided between each line to ground.
75 V
Features
■
■
■
■
■
■
■
2026 Series - 3-Pole Gas Discharge Tube
Balanced TRIGARD
Approximately 8 mm diameter, 11 mm long
UL recognized
Custom confi gurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
80 V for Model 2026-15)
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ...................................................
1000 A, 10/1000 µs ................................................. > 400 operations
20 Arms, 1 s ............................................................. > 10 operations
2026-09
2026-30
275 V
600 V
300 V
500 V
775 V
90 V
®
2026-15
2026-35
3
150 V
350 V
575 V
350 V
625 V
875 V
....................................................
3
...............................................
Model No.
2026-20
2026-40
200 V
425 V
625 V
400 V
675 V
925 V
Model No.
Applications
■
■
■
■
■
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
2026-23
2026-42
1000 V
230 V
450 V
650 V
420 V
725 V
1 operation minimum
1 operation
1 operation minimum
40/ 90/ 21
2026-25
2026-47
10
1100 V
250 V
475 V
700 V
470 V
800 V
Ω
2026-26
2026-60
1250 V
260V
475 V
700 V
600 V
925 V
1