MAX16031ETM+ Maxim Integrated Products, MAX16031ETM+ Datasheet - Page 23

IC SYSTEM MON EEPROM 48-TQFN

MAX16031ETM+

Manufacturer Part Number
MAX16031ETM+
Description
IC SYSTEM MON EEPROM 48-TQFN
Manufacturer
Maxim Integrated Products
Type
Multi-Voltage Supervisorr
Datasheet

Specifications of MAX16031ETM+

Number Of Voltages Monitored
8
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
8 Selectable Threshold Combinations
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFN Exposed Pad
Manual Reset
Resettable
Watchdog
No Watchdog
Supply Voltage (max)
14 V
Supply Voltage (min)
2.9 V
Supply Current (typ)
3000 uA
Maximum Power Dissipation
2222.2 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 8. Output Dependencies
REGISTER
ADDRESS
1Dh
1Eh
1Fh
ADDRESS
MEMORY
EEPROM
9Dh
9Eh
9Fh
______________________________________________________________________________________
BIT RANGE
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
EEPROM-Based System Monitors
1 = FAULT1 depends on the secondary undervoltage thresholds of all enabled IN1–IN8.
1 = FAULT1 depends on the primary overvoltage thresholds of all enabled IN1–IN8.
1 = FAULT1 depends on the secondary overvoltage thresholds of all enabled IN1–IN8.
1 = FAULT1 depends on the secondary overtemperature threshold of the internal
temperature sensor.
1 = FAULT1 depends on the secondary overtemperature threshold of remote
temperature sensor 1.
1 = FAULT1 depends on the secondary overtemperature threshold of remote
temperature sensor 2.
1 = FAULT1 depends on the secondary overcurrent threshold.
Reserved
1 = FAULT2 depends on the secondary undervoltage thresholds of all enabled IN1–IN8.
1 = FAULT2 depends on the primary overvoltage thresholds of all enabled IN1–IN8.
1 = FAULT2 depends on the secondary overvoltage thresholds of all enabled IN1–IN8.
1 = FAULT2 depends on the secondary overtemperature threshold of the internal
temperature sensor.
1 = FAULT2 depends on the secondary overtemperature threshold of remote
temperature sensor 1.
1 = FAULT2 depends on the secondary overtemperature threshold of remote
temperature sensor 2.
1 = FAULT2 depends on the secondary overcurrent threshold.
Reserved
1 = OVERT depends on the primary overtemperature threshold of the internal
temperature sensor.
1 = OVERT depends on the primary overtemperature threshold of the remote
temperature sensor 1.
1 = OVERT depends on the primary overtemperature threshold of the remote
temperature sensor 2.
with Nonvolatile Fault Memory
DESCRIPTION
23

Related parts for MAX16031ETM+